ARM: rockchip: add power-management-unit
The pmu is needed to bring up the cores during smp operations and later also other system parts. Therefore add a node and documentation for it. Signed-off-by: Heiko Stuebner <heiko@sntech.de> Tested-by: Ulrich Prinz <ulrich.prinz@googlemail.com>
This commit is contained in:
parent
de18e01478
commit
46b8219c51
16
Documentation/devicetree/bindings/arm/rockchip/pmu.txt
Normal file
16
Documentation/devicetree/bindings/arm/rockchip/pmu.txt
Normal file
@ -0,0 +1,16 @@
|
||||
Rockchip power-management-unit:
|
||||
-------------------------------
|
||||
|
||||
The pmu is used to turn off and on different power domains of the SoCs
|
||||
This includes the power to the CPU cores.
|
||||
|
||||
Required node properties:
|
||||
- compatible value : = "rockchip,rk3066-pmu";
|
||||
- reg : physical base address and the size of the registers window
|
||||
|
||||
Example:
|
||||
|
||||
pmu@20004000 {
|
||||
compatible = "rockchip,rk3066-pmu";
|
||||
reg = <0x20004000 0x100>;
|
||||
};
|
@ -31,6 +31,11 @@
|
||||