mirror of
https://mirrors.bfsu.edu.cn/git/linux.git
synced 2024-11-28 06:34:12 +08:00
thermal: exynos: Fix wrong control of power down detection mode for Exynos7
This patch fixes the wrong control of PD_DET_EN (power down detection mode) for Exynos7 because exynos7_tmu_control() always enables the power down detection mode regardless 'on' parameter. Cc: Zhang Rui <rui.zhang@intel.com> Cc: Eduardo Valentin <edubezval@gmail.com> Signed-off-by: Chanwoo Choi <cw00.choi@samsung.com> Tested-by: Abhilash Kesavan <a.kesavan@samsung.com> Signed-off-by: Lukasz Majewski <l.majewski@samsung.com>
This commit is contained in:
parent
5912e264d9
commit
42b696e808
@ -682,6 +682,7 @@ static void exynos7_tmu_control(struct platform_device *pdev, bool on)
|
||||
|
||||
if (on) {
|
||||
con |= (1 << EXYNOS_TMU_CORE_EN_SHIFT);
|
||||
con |= (1 << EXYNOS7_PD_DET_EN_SHIFT);
|
||||
interrupt_en =
|
||||
(of_thermal_is_trip_valid(tz, 7)
|
||||
<< EXYNOS7_TMU_INTEN_RISE7_SHIFT) |
|
||||
@ -704,9 +705,9 @@ static void exynos7_tmu_control(struct platform_device *pdev, bool on)
|
||||
interrupt_en << EXYNOS_TMU_INTEN_FALL0_SHIFT;
|
||||
} else {
|
||||
con &= ~(1 << EXYNOS_TMU_CORE_EN_SHIFT);
|
||||
con &= ~(1 << EXYNOS7_PD_DET_EN_SHIFT);
|
||||
interrupt_en = 0; /* Disable all interrupts */
|
||||
}
|
||||
con |= 1 << EXYNOS7_PD_DET_EN_SHIFT;
|
||||
|
||||
writel(interrupt_en, data->base + EXYNOS7_TMU_REG_INTEN);
|
||||
writel(con, data->base + EXYNOS_TMU_REG_CONTROL);
|
||||
|