interconnect: exynos: fix node leak in probe PM QoS error path
Make sure to add the newly allocated interconnect node to the provider
before adding the PM QoS request so that the node is freed on errors.
Fixes: 2f95b9d5cf
("interconnect: Add generic interconnect driver for Exynos SoCs")
Cc: stable@vger.kernel.org # 5.11
Cc: Sylwester Nawrocki <s.nawrocki@samsung.com>
Reviewed-by: Krzysztof Kozlowski <krzysztof.kozlowski@linaro.org>
Signed-off-by: Johan Hovold <johan+linaro@kernel.org>
Link: https://lore.kernel.org/r/20230306075651.2449-15-johan+linaro@kernel.org
Signed-off-by: Georgi Djakov <djakov@kernel.org>
This commit is contained in:
parent
bfe7bcd2b9
commit
3aab264875
@ -149,6 +149,9 @@ static int exynos_generic_icc_probe(struct platform_device *pdev)
|
||||
&priv->bus_clk_ratio))
|
||||
priv->bus_clk_ratio = EXYNOS_ICC_DEFAULT_BUS_CLK_RATIO;
|
||||
|
||||
icc_node->data = priv;
|
||||
icc_node_add(icc_node, provider);
|
||||
|
||||
/*
|
||||
* Register a PM QoS request for the parent (devfreq) device.
|
||||
*/
|
||||
@ -157,9 +160,6 @@ static int exynos_generic_icc_probe(struct platform_device *pdev)
|
||||
if (ret < 0)
|
||||
goto err_node_del;
|
||||
|
||||
icc_node->data = priv;
|
||||
icc_node_add(icc_node, provider);
|
||||
|
||||
icc_parent_node = exynos_icc_get_parent(bus_dev->of_node);
|
||||
if (IS_ERR(icc_parent_node)) {
|
||||
ret = PTR_ERR(icc_parent_node);
|
||||
|
Loading…