drm/bridge: adv7511: Enable connector polling when no interrupt is specified
Fall back to polling the connector for connect and disconnect events when no interrupt is specified. Otherwise these events will not be noticed and monitor hotplug does not work. Signed-off-by: Lars-Peter Clausen <lars@metafoo.de> Tested-by: John Stultz <john.stultz@linaro.org> Signed-off-by: Archit Taneja <architt@codeaurora.org> Link: https://patchwork.freedesktop.org/patch/msgid/20170905121018.11477-3-lars@metafoo.de
This commit is contained in:
parent
fcb4c5eee7
commit
2f47f1c106
@ -829,7 +829,11 @@ static int adv7511_bridge_attach(struct drm_bridge *bridge)
|
||||
return -ENODEV;
|
||||
}
|
||||
|
||||
if (adv->i2c_main->irq)
|
||||
adv->connector.polled = DRM_CONNECTOR_POLL_HPD;
|
||||
else
|
||||
adv->connector.polled = DRM_CONNECTOR_POLL_CONNECT |
|
||||
DRM_CONNECTOR_POLL_DISCONNECT;
|
||||
|
||||
ret = drm_connector_init(bridge->dev, &adv->connector,
|
||||
&adv7511_connector_funcs,
|
||||
|