thermal: rcar_gen3_thermal: update max temperature clamp

Change the upper limit to clamp the high temperature value to 120C when
setting trip points.

Signed-off-by: Niklas Söderlund <niklas.soderlund+renesas@ragnatech.se>
Reviewed-by: Simon Horman <horms+renesas@verge.net.au>
Signed-off-by: Eduardo Valentin <edubezval@gmail.com>
This commit is contained in:
Niklas Söderlund 2018-04-17 22:57:47 +02:00 committed by Eduardo Valentin
parent fc66ddff38
commit 270ba43200

View File

@ -207,8 +207,8 @@ static int rcar_gen3_thermal_set_trips(void *devdata, int low, int high)
{
struct rcar_gen3_thermal_tsc *tsc = devdata;
low = clamp_val(low, -40000, 125000);
high = clamp_val(high, -40000, 125000);
low = clamp_val(low, -40000, 120000);
high = clamp_val(high, -40000, 120000);
rcar_gen3_thermal_write(tsc, REG_GEN3_IRQTEMP1,
rcar_gen3_thermal_mcelsius_to_temp(tsc, low));