mirror of
https://mirrors.bfsu.edu.cn/git/linux.git
synced 2024-11-15 16:24:13 +08:00
power: bq27xxx: don't fill system log by missing battery
Print message that battery is not calibrated only once to avoid spamming the log. Suggested-By: H. Nikolaus Schaller <hns@goldelico.com> Suggested-By: Pali Rohár <pali.rohar@gmail.com> Signed-off-by: Sebastian Reichel <sre@kernel.org>
This commit is contained in:
parent
d5fdfedc0e
commit
1f94b2563a
@ -722,7 +722,7 @@ static void bq27xxx_battery_update(struct bq27xxx_device_info *di)
|
||||
if (cache.flags >= 0) {
|
||||
cache.temperature = bq27xxx_battery_read_temperature(di);
|
||||
if (has_ci_flag && (cache.flags & BQ27000_FLAG_CI)) {
|
||||
dev_info(di->dev, "battery is not calibrated! ignoring capacity values\n");
|
||||
dev_info_once(di->dev, "battery is not calibrated! ignoring capacity values\n");
|
||||
cache.capacity = -ENODATA;
|
||||
cache.energy = -ENODATA;
|
||||
cache.time_to_empty = -ENODATA;
|
||||
|
Loading…
Reference in New Issue
Block a user