pata_it821x: Fix RAID type display, by adding missing comma
The missing comma causes the wrong RAID type to be displayed.
Introduced by commit 963e4975c6
three
years ago, odd that nobody noticed before.
Signed-off-by: Jean Delvare <khali@linux-fr.org>
Cc: Jeff Garzik <jgarzik@pobox.com>
Cc: Alan Cox <alan@lxorguk.ukuu.org.uk>
Signed-off-by: Jeff Garzik <jgarzik@pobox.com>
This commit is contained in:
parent
04e506b5e7
commit
1c30c02757
@ -610,7 +610,7 @@ static void it821x_display_disk(int n, u8 *buf)
|
||||
char *cbl = "(40 wire cable)";
|
||||
|
||||
static const char *types[5] = {
|
||||
"RAID0", "RAID1" "RAID 0+1", "JBOD", "DISK"
|
||||
"RAID0", "RAID1", "RAID 0+1", "JBOD", "DISK"
|
||||
};
|
||||
|
||||
if (buf[52] > 4) /* No Disk */
|
||||
|