cdc-acm: Add DISABLE_ECHO quirk for GE HealthCare UI Controller

USB_DEVICE(0x1901, 0x0006) may send data before cdc_acm is ready, which
may be misinterpreted in the default N_TTY line discipline.

Signed-off-by: Ian Ray <ian.ray@gehealthcare.com>
Acked-by: Oliver Neuku <oneukum@suse.com>
Cc: stable <stable@kernel.org>
Link: https://lore.kernel.org/r/20240814072905.2501-1-ian.ray@gehealthcare.com
Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
This commit is contained in:
Ian Ray 2024-08-14 10:29:05 +03:00 committed by Greg Kroah-Hartman
parent 0497a356d3
commit 0b00583eca

View File

@ -1761,6 +1761,9 @@ static const struct usb_device_id acm_ids[] = {
{ USB_DEVICE(0x11ca, 0x0201), /* VeriFone Mx870 Gadget Serial */
.driver_info = SINGLE_RX_URB,
},
{ USB_DEVICE(0x1901, 0x0006), /* GE Healthcare Patient Monitor UI Controller */
.driver_info = DISABLE_ECHO, /* DISABLE ECHO in termios flag */
},
{ USB_DEVICE(0x1965, 0x0018), /* Uniden UBC125XLT */
.driver_info = NO_UNION_NORMAL, /* has no union descriptor */
},