power: supply: charger-manager: Swap private uevent for power_supply_changed
Whenever the battery status is changed, charger manager triggers a uevent through a private interface. Modify it to use power_supply_changed() since it belongs to the power supply subsystem. Signed-off-by: Jonghwa Lee <jonghwa3.lee@samsung.com> Signed-off-by: Krzysztof Kozlowski <k.kozlowski@samsung.com> Signed-off-by: Jonathan Bakker <xc-racer2@live.ca> Signed-off-by: Sebastian Reichel <sebastian.reichel@collabora.com>
This commit is contained in:
parent
1426dffad0
commit
033dea165c
@ -33,18 +33,6 @@
|
||||
#define CM_DEFAULT_RECHARGE_TEMP_DIFF 50
|
||||
#define CM_DEFAULT_CHARGE_TEMP_MAX 500
|
||||
|
||||
static const char * const default_event_names[] = {
|
||||
[CM_EVENT_UNKNOWN] = "Unknown",
|
||||
[CM_EVENT_BATT_FULL] = "Battery Full",
|
||||
[CM_EVENT_BATT_IN] = "Battery Inserted",
|
||||
[CM_EVENT_BATT_OUT] = "Battery Pulled Out",
|
||||
[CM_EVENT_BATT_OVERHEAT] = "Battery Overheat",
|
||||
[CM_EVENT_BATT_COLD] = "Battery Cold",
|
||||
[CM_EVENT_EXT_PWR_IN_OUT] = "External Power Attach/Detach",
|
||||
[CM_EVENT_CHG_START_STOP] = "Charging Start/Stop",
|
||||
[CM_EVENT_OTHERS] = "Other battery events"
|
||||
};
|
||||
|
||||
/*
|
||||
* Regard CM_JIFFIES_SMALL jiffies is small enough to ignore for
|
||||
* delayed works so that we can run delayed works with CM_JIFFIES_SMALL
|
||||
@ -61,8 +49,6 @@ static const char * const default_event_names[] = {
|
||||
*/
|
||||
#define CM_RTC_SMALL (2)
|
||||
|
||||
#define UEVENT_BUF_SIZE 32
|
||||
|
||||
static LIST_HEAD(cm_list);
|
||||
static DEFINE_MUTEX(cm_list_mtx);
|
||||
|
||||
@ -446,61 +432,6 @@ static int try_charger_restart(struct charger_manager *cm)
|
||||
return try_charger_enable(cm, true);
|
||||
}
|
||||
|
||||
/**
|
||||
* uevent_notify - Let users know something has changed.
|
||||
* @cm: the Charger Manager representing the battery.
|
||||
* @event: the event string.
|
||||
*
|
||||
* If @event is null, it implies that uevent_notify is called
|
||||
* by resume function. When called in the resume function, cm_suspended
|
||||
* should be already reset to false in order to let uevent_notify
|
||||
* notify the recent event during the suspend to users. While
|
||||
* suspended, uevent_notify does not notify users, but tracks
|
||||
* events so that uevent_notify can notify users later after resumed.
|
||||
*/
|
||||
static void uevent_notify(struct charger_manager *cm, const char *event)
|
||||
{
|
||||
static char env_str[UEVENT_BUF_SIZE + 1] = "";
|
||||
static char env_str_save[UEVENT_BUF_SIZE + 1] = "";
|
||||
|
||||
if (cm_suspended) {
|
||||
/* Nothing in suspended-event buffer */
|
||||
if (env_str_save[0] == 0) {
|
||||
if (!strncmp(env_str, event, UEVENT_BUF_SIZE))
|
||||
return; /* status not changed */
|
||||
strncpy(env_str_save, event, UEVENT_BUF_SIZE);
|
||||
return;
|
||||
}
|
||||
|
||||
if (!strncmp(env_str_save, event, UEVENT_BUF_SIZE))
|
||||
return; /* Duplicated. */
|
||||
strncpy(env_str_save, event, UEVENT_BUF_SIZE);
|
||||
return;
|
||||
}
|
||||
|
||||
if (event == NULL) {
|
||||
/* No messages pending */
|
||||
if (!env_str_save[0])
|
||||
return;
|
||||
|
||||
strncpy(env_str, env_str_save, UEVENT_BUF_SIZE);
|
||||
kobject_uevent(&cm->dev->kobj, KOBJ_CHANGE);
|
||||
env_str_save[0] = 0;
|
||||
|
||||
return;
|
||||
}
|
||||
|
||||
/* status not changed */
|
||||
if (!strncmp(env_str, event, UEVENT_BUF_SIZE))
|
||||
return;
|
||||
|
||||
/* save the status and notify the update */
|
||||
strncpy(env_str, event, UEVENT_BUF_SIZE);
|
||||
kobject_uevent(&cm->dev->kobj, KOBJ_CHANGE);
|
||||
|
||||
dev_info(cm->dev, "%s\n", event);
|
||||
}
|
||||
|
||||
/**
|
||||
* fullbatt_vchk - Check voltage drop some times after "FULL" event.
|
||||
* @work: the work_struct appointing the function
|
||||
@ -538,7 +469,7 @@ static void fullbatt_vchk(struct work_struct *work)
|
||||
|
||||
if (diff > desc->fullbatt_vchkdrop_uV) {
|
||||
try_charger_restart(cm);
|
||||
uevent_notify(cm, "Recharging");
|
||||
power_supply_changed(cm->charger_psy);
|
||||
}
|
||||
}
|
||||
|
||||
@ -569,7 +500,7 @@ static int check_charging_duration(struct charger_manager *cm)
|
||||
if (duration > desc->charging_max_duration_ms) {
|
||||
dev_info(cm->dev, "Charging duration exceed %ums\n",
|
||||
desc->charging_max_duration_ms);
|
||||
uevent_notify(cm, "Discharging");
|
||||
power_supply_changed(cm->charger_psy);
|
||||
try_charger_enable(cm, false);
|
||||
ret = true;
|
||||
}
|
||||
@ -580,7 +511,7 @@ static int check_charging_duration(struct charger_manager *cm)
|
||||
is_ext_pwr_online(cm)) {
|
||||
dev_info(cm->dev, "Discharging duration exceed %ums\n",
|
||||
desc->discharging_max_duration_ms);
|
||||
uevent_notify(cm, "Recharging");
|
||||
power_supply_changed(cm->charger_psy);
|
||||
try_charger_enable(cm, true);
|
||||
ret = true;
|
||||
}
|
||||
@ -688,7 +619,7 @@ static bool _cm_monitor(struct charger_manager *cm)
|
||||
if (temp_alrt) {
|
||||
cm->emergency_stop = temp_alrt;
|
||||
if (!try_charger_enable(cm, false))
|
||||
uevent_notify(cm, default_event_names[temp_alrt]);
|
||||
power_supply_changed(cm->charger_psy);
|
||||
|
||||
/*
|
||||
* Check whole charging duration and discharging duration
|
||||
@ -713,7 +644,7 @@ static bool _cm_monitor(struct charger_manager *cm)
|
||||
} else if (!cm->emergency_stop && is_full_charged(cm) &&
|
||||
cm->charger_enabled) {
|
||||
dev_info(cm->dev, "EVENT_HANDLE: Battery Fully Charged\n");
|
||||
uevent_notify(cm, default_event_names[CM_EVENT_BATT_FULL]);
|
||||
power_supply_changed(cm->charger_psy);
|
||||
|
||||
try_charger_enable(cm, false);
|
||||
|
||||
@ -722,7 +653,7 @@ static bool _cm_monitor(struct charger_manager *cm)
|
||||
cm->emergency_stop = 0;
|
||||
if (is_ext_pwr_online(cm)) {
|
||||
if (!try_charger_enable(cm, true))
|
||||
uevent_notify(cm, "CHARGING");
|
||||
power_supply_changed(cm->charger_psy);
|
||||
}
|
||||
}
|
||||
|
||||
@ -843,7 +774,7 @@ static void fullbatt_handler(struct charger_manager *cm)
|
||||
|
||||
out:
|
||||
dev_info(cm->dev, "EVENT_HANDLE: Battery Fully Charged\n");
|
||||
uevent_notify(cm, default_event_names[CM_EVENT_BATT_FULL]);
|
||||
power_supply_changed(cm->charger_psy);
|
||||
}
|
||||
|
||||
/**
|
||||
@ -857,9 +788,9 @@ static void battout_handler(struct charger_manager *cm)
|
||||
|
||||
if (!is_batt_present(cm)) {
|
||||
dev_emerg(cm->dev, "Battery Pulled Out!\n");
|
||||
uevent_notify(cm, default_event_names[CM_EVENT_BATT_OUT]);
|
||||
power_supply_changed(cm->charger_psy);
|
||||
} else {
|
||||
uevent_notify(cm, "Battery Reinserted?");
|
||||
power_supply_changed(cm->charger_psy);
|
||||
}
|
||||
}
|
||||
|
||||
@ -876,7 +807,7 @@ static void misc_event_handler(struct charger_manager *cm,
|
||||
|
||||
if (is_polling_required(cm) && cm->desc->polling_interval_ms)
|
||||
schedule_work(&setup_polling);
|
||||
uevent_notify(cm, default_event_names[type]);
|
||||
power_supply_changed(cm->charger_psy);
|
||||
}
|
||||
|
||||
static int charger_get_property(struct power_supply *psy,
|
||||
@ -2048,7 +1979,7 @@ void cm_notify_event(struct power_supply *psy, enum cm_event_types type,
|
||||
break;
|
||||
case CM_EVENT_UNKNOWN:
|
||||
case CM_EVENT_OTHERS:
|
||||
uevent_notify(cm, msg ? msg : default_event_names[type]);
|
||||
power_supply_changed(cm->charger_psy);
|
||||
break;
|
||||
default:
|
||||
dev_err(cm->dev, "%s: type not specified\n", __func__);
|
||||
|