2019-05-19 20:07:45 +08:00
|
|
|
# SPDX-License-Identifier: GPL-2.0-only
|
2017-06-23 16:28:18 +08:00
|
|
|
menu "Amlogic SoC drivers"
|
|
|
|
|
2018-08-23 19:49:53 +08:00
|
|
|
config MESON_CANVAS
|
|
|
|
tristate "Amlogic Meson Canvas driver"
|
|
|
|
depends on ARCH_MESON || COMPILE_TEST
|
|
|
|
default n
|
|
|
|
help
|
|
|
|
Say yes to support the canvas IP for Amlogic SoCs.
|
|
|
|
|
2018-11-18 21:50:23 +08:00
|
|
|
config MESON_CLK_MEASURE
|
|
|
|
bool "Amlogic Meson SoC Clock Measure driver"
|
|
|
|
depends on ARCH_MESON || COMPILE_TEST
|
|
|
|
default ARCH_MESON
|
2018-12-11 03:45:55 +08:00
|
|
|
select REGMAP_MMIO
|
2018-11-18 21:50:23 +08:00
|
|
|
help
|
|
|
|
Say yes to support of Measuring a set of internal SoC clocks
|
|
|
|
from the debugfs interface.
|
|
|
|
|
2017-06-23 16:28:18 +08:00
|
|
|
config MESON_GX_SOCINFO
|
|
|
|
bool "Amlogic Meson GX SoC Information driver"
|
|
|
|
depends on ARCH_MESON || COMPILE_TEST
|
|
|
|
default ARCH_MESON
|
|
|
|
select SOC_BUS
|
|
|
|
help
|
|
|
|
Say yes to support decoding of Amlogic Meson GX SoC family
|
|
|
|
information about the type, package and version.
|
|
|
|
|
2017-10-29 00:40:16 +08:00
|
|
|
config MESON_GX_PM_DOMAINS
|
|
|
|
bool "Amlogic Meson GX Power Domains driver"
|
|
|
|
depends on ARCH_MESON || COMPILE_TEST
|
2017-11-03 06:39:54 +08:00
|
|
|
depends on PM && OF
|
2017-10-29 00:40:16 +08:00
|
|
|
default ARCH_MESON
|
|
|
|
select PM_GENERIC_DOMAINS
|
|
|
|
select PM_GENERIC_DOMAINS_OF
|
|
|
|
help
|
|
|
|
Say yes to expose Amlogic Meson GX Power Domains as
|
|
|
|
Generic Power Domains.
|
|
|
|
|
2019-08-23 17:04:15 +08:00
|
|
|
config MESON_EE_PM_DOMAINS
|
|
|
|
bool "Amlogic Meson Everything-Else Power Domains driver"
|
|
|
|
depends on ARCH_MESON || COMPILE_TEST
|
|
|
|
depends on PM && OF
|
|
|
|
default ARCH_MESON
|
|
|
|
select PM_GENERIC_DOMAINS
|
|
|
|
select PM_GENERIC_DOMAINS_OF
|
|
|
|
help
|
|
|
|
Say yes to expose Amlogic Meson Everything-Else Power Domains as
|
|
|
|
Generic Power Domains.
|
|
|
|
|
2020-01-15 19:30:30 +08:00
|
|
|
config MESON_SECURE_PM_DOMAINS
|
|
|
|
bool "Amlogic Meson Secure Power Domains driver"
|
2020-02-18 00:12:13 +08:00
|
|
|
depends on (ARCH_MESON || COMPILE_TEST) && MESON_SM
|
2020-01-15 19:30:30 +08:00
|
|
|
depends on PM && OF
|
|
|
|
depends on HAVE_ARM_SMCCC
|
|
|
|
default ARCH_MESON
|
|
|
|
select PM_GENERIC_DOMAINS
|
|
|
|
select PM_GENERIC_DOMAINS_OF
|
|
|
|
help
|
|
|
|
Support for the power controller on Amlogic A1/C1 series.
|
|
|
|
Say yes to expose Amlogic Meson Secure Power Domains as Generic
|
|
|
|
Power Domains.
|
|
|
|
|
2017-09-23 22:14:02 +08:00
|
|
|
config MESON_MX_SOCINFO
|
|
|
|
bool "Amlogic Meson MX SoC Information driver"
|
|
|
|
depends on ARCH_MESON || COMPILE_TEST
|
|
|
|
default ARCH_MESON
|
|
|
|
select SOC_BUS
|
|
|
|
help
|
|
|
|
Say yes to support decoding of Amlogic Meson6, Meson8,
|
|
|
|
Meson8b and Meson8m2 SoC family information about the type
|
|
|
|
and version.
|
|
|
|
|
2017-06-23 16:28:18 +08:00
|
|
|
endmenu
|