mirror of
https://mirrors.bfsu.edu.cn/git/linux.git
synced 2024-11-16 16:54:20 +08:00
101 lines
3.5 KiB
Plaintext
101 lines
3.5 KiB
Plaintext
|
|
||
|
HPSA - Hewlett Packard Smart Array driver
|
||
|
-----------------------------------------
|
||
|
|
||
|
This file describes the hpsa SCSI driver for HP Smart Array controllers.
|
||
|
The hpsa driver is intended to supplant the cciss driver for newer
|
||
|
Smart Array controllers. The hpsa driver is a SCSI driver, while the
|
||
|
cciss driver is a "block" driver. Actually cciss is both a block
|
||
|
driver (for logical drives) AND a SCSI driver (for tape drives). This
|
||
|
"split-brained" design of the cciss driver is a source of excess
|
||
|
complexity and eliminating that complexity is one of the reasons
|
||
|
for hpsa to exist.
|
||
|
|
||
|
Supported devices:
|
||
|
------------------
|
||
|
|
||
|
Smart Array P212
|
||
|
Smart Array P410
|
||
|
Smart Array P410i
|
||
|
Smart Array P411
|
||
|
Smart Array P812
|
||
|
Smart Array P712m
|
||
|
Smart Array P711m
|
||
|
StorageWorks P1210m
|
||
|
|
||
|
Additionally, older Smart Arrays may work with the hpsa driver if the kernel
|
||
|
boot parameter "hpsa_allow_any=1" is specified, however these are not tested
|
||
|
nor supported by HP with this driver. For older Smart Arrays, the cciss
|
||
|
driver should still be used.
|
||
|
|
||
|
HPSA specific entries in /sys
|
||
|
-----------------------------
|
||
|
|
||
|
In addition to the generic SCSI attributes available in /sys, hpsa supports
|
||
|
the following attributes:
|
||
|
|
||
|
HPSA specific host attributes:
|
||
|
------------------------------
|
||
|
|
||
|
/sys/class/scsi_host/host*/rescan
|
||
|
|
||
|
the host "rescan" attribute is a write only attribute. Writing to this
|
||
|
attribute will cause the driver to scan for new, changed, or removed devices
|
||
|
(e.g. hot-plugged tape drives, or newly configured or deleted logical drives,
|
||
|
etc.) and notify the SCSI midlayer of any changes detected. Normally this is
|
||
|
triggered automatically by HP's Array Configuration Utility (either the GUI or
|
||
|
command line variety) so for logical drive changes, the user should not
|
||
|
normally have to use this. It may be useful when hot plugging devices like
|
||
|
tape drives, or entire storage boxes containing pre-configured logical drives.
|
||
|
|
||
|
HPSA specific disk attributes:
|
||
|
------------------------------
|
||
|
|
||
|
/sys/class/scsi_disk/c:b:t:l/device/unique_id
|
||
|
/sys/class/scsi_disk/c:b:t:l/device/raid_level
|
||
|
/sys/class/scsi_disk/c:b:t:l/device/lunid
|
||
|
|
||
|
(where c:b:t:l are the controller, bus, target and lun of the device)
|
||
|
|
||
|
For example:
|
||
|
|
||
|
root@host:/sys/class/scsi_disk/4:0:0:0/device# cat unique_id
|
||
|
600508B1001044395355323037570F77
|
||
|
root@host:/sys/class/scsi_disk/4:0:0:0/device# cat lunid
|
||
|
0x0000004000000000
|
||
|
root@host:/sys/class/scsi_disk/4:0:0:0/device# cat raid_level
|
||
|
RAID 0
|
||
|
|
||
|
HPSA specific ioctls:
|
||
|
---------------------
|
||
|
|
||
|
For compatibility with applications written for the cciss driver, many, but
|
||
|
not all of the ioctls supported by the cciss driver are also supported by the
|
||
|
hpsa driver. The data structures used by these are described in
|
||
|
include/linux/cciss_ioctl.h
|
||
|
|
||
|
CCISS_DEREGDISK
|
||
|
CCISS_REGNEWDISK
|
||
|
CCISS_REGNEWD
|
||
|
|
||
|
The above three ioctls all do exactly the same thing, which is to cause the driver
|
||
|
to rescan for new devices. This does exactly the same thing as writing to the
|
||
|
hpsa specific host "rescan" attribute.
|
||
|
|
||
|
CCISS_GETPCIINFO
|
||
|
|
||
|
Returns PCI domain, bus, device and function and "board ID" (PCI subsystem ID).
|
||
|
|
||
|
CCISS_GETDRIVVER
|
||
|
|
||
|
Returns driver version in three bytes encoded as:
|
||
|
(major_version << 16) | (minor_version << 8) | (subminor_version)
|
||
|
|
||
|
CCISS_PASSTHRU
|
||
|
CCISS_BIG_PASSTHRU
|
||
|
|
||
|
Allows "BMIC" and "CISS" commands to be passed through to the Smart Array.
|
||
|
These are used extensively by the HP Array Configuration Utility, SNMP storage
|
||
|
agents, etc. See cciss_vol_status at http://cciss.sf.net for some examples.
|
||
|
|