bluez/test/test-health
Petri Gynther 7adf8d09b4 test: Python import cleanup
Some test scripts use "from gi.repository import GObject" whereas others
use "import gobject". gi.repository is not always available on embedded
systems, so convert all instances to this format:

try:
  from gi.repository import GObject
except ImportError:
  import gobject as GObject

Also, sort the imports in this order: system, dbus, gobject, bluezutils
2014-01-18 00:38:39 -08:00

233 lines
4.9 KiB
Python
Executable File

#!/usr/bin/python
from __future__ import absolute_import, print_function, unicode_literals
# -*- coding: utf-8 -*-
import sys
import dbus
import dbus.service
from dbus.mainloop.glib import DBusGMainLoop
try:
from gi.repository import GObject
except ImportError:
import gobject as GObject
BUS_NAME = 'org.bluez'
PATH = '/org/bluez'
ADAPTER_INTERFACE = 'org.bluez.Adapter1'
HEALTH_MANAGER_INTERFACE = 'org.bluez.HealthManager1'
HEALTH_DEVICE_INTERFACE = 'org.bluez.HealthDevice1'
DBusGMainLoop(set_as_default=True)
loop = GObject.MainLoop()
bus = dbus.SystemBus()
def sig_received(*args, **kwargs):
if "member" not in kwargs:
return
if "path" not in kwargs:
return;
sig_name = kwargs["member"]
path = kwargs["path"]
print(sig_name)
print(path)
if sig_name == "PropertyChanged":
k, v = args
print(k)
print(v)
else:
ob = args[0]
print(ob)
def enter_mainloop():
bus.add_signal_receiver(sig_received, bus_name=BUS_NAME,
dbus_interface=HEALTH_DEVICE_INTERFACE,
path_keyword="path",
member_keyword="member",
interface_keyword="interface")
try:
print("Entering main lopp, push Ctrl+C for finish")
mainloop = GObject.MainLoop()
mainloop.run()
except KeyboardInterrupt:
pass
finally:
print("Exiting, bye")
hdp_manager = dbus.Interface(bus.get_object(BUS_NAME, PATH),
HEALTH_MANAGER_INTERFACE)
role = None
while role == None:
print("Select 1. source or 2. sink: ",)
try:
sel = int(sys.stdin.readline())
if sel == 1:
role = "source"
elif sel == 2:
role = "sink"
else:
raise ValueError
except (TypeError, ValueError):
print("Wrong selection, try again: ",)
except KeyboardInterrupt:
sys.exit()
dtype = None
while dtype == None:
print("Select a data type: ",)
try:
sel = int(sys.stdin.readline())
if (sel < 0) or (sel > 65535):
raise ValueError
dtype = sel;
except (TypeError, ValueError):
print("Wrong selection, try again: ",)
except KeyboardInterrupt:
sys.exit()
pref = None
if role == "source":
while pref == None:
try:
print("Select a preferred data channel type 1.",)
print("reliable 2. streaming: ",)
sel = int(sys.stdin.readline())
if sel == 1:
pref = "reliable"
elif sel == 2:
pref = "streaming"
else:
raise ValueError
except (TypeError, ValueError):
print("Wrong selection, try again")
except KeyboardInterrupt:
sys.exit()
app_path = hdp_manager.CreateApplication({
"DataType": dbus.types.UInt16(dtype),
"Role": role,
"Description": "Test Source",
"ChannelType": pref})
else:
app_path = hdp_manager.CreateApplication({
"DataType": dbus.types.UInt16(dtype),
"Description": "Test sink",
"Role": role})
print("New application created:", app_path)
con = None
while con == None:
try:
print("Connect to a remote device (y/n)? ",)
sel = sys.stdin.readline()
if sel in ("y\n", "yes\n", "Y\n", "YES\n"):
con = True
elif sel in ("n\n", "no\n", "N\n", "NO\n"):
con = False
else:
print("Wrong selection, try again.")
except KeyboardInterrupt:
sys.exit()
if not con:
enter_mainloop()
sys.exit()
manager = dbus.Interface(bus.get_object(BUS_NAME, "/"),
"org.freedesktop.DBus.ObjectManager")
objects = manager.GetManagedObjects()
adapters = []
for path, ifaces in objects.iteritems():
if ifaces.has_key(ADAPTER_INTERFACE):
adapters.append(path)
i = 1
for ad in adapters:
print("%d. %s" % (i, ad))
i = i + 1
print("Select an adapter: ",)
select = None
while select == None:
try:
pos = int(sys.stdin.readline()) - 1
if pos < 0:
raise TypeError
select = adapters[pos]
except (TypeError, IndexError, ValueError):
print("Wrong selection, try again: ",)
except KeyboardInterrupt:
sys.exit()
adapter = dbus.Interface(bus.get_object(BUS_NAME, select), ADAPTER_INTERFACE)
devices = adapter.GetProperties()["Devices"]
if len(devices) == 0:
print("No devices available")
sys.exit()
i = 1
for dev in devices:
print("%d. %s" % (i, dev))
i = i + 1
print("Select a device: ",)
select = None
while select == None:
try:
pos = int(sys.stdin.readline()) - 1
if pos < 0:
raise TypeError
select = devices[pos]
except (TypeError, IndexError, ValueError):
print("Wrong selection, try again: ",)
except KeyboardInterrupt:
sys.exit()
device = dbus.Interface(bus.get_object(BUS_NAME, select),
HEALTH_DEVICE_INTERFACE)
echo = None
while echo == None:
try:
print("Perform an echo (y/n)? ",)
sel = sys.stdin.readline()
if sel in ("y\n", "yes\n", "Y\n", "YES\n"):
echo = True
elif sel in ("n\n", "no\n", "N\n", "NO\n"):
echo = False
else:
print("Wrong selection, try again.")
except KeyboardInterrupt:
sys.exit()
if echo:
if device.Echo():
print("Echo was ok")
else:
print("Echo war wrong, exiting")
sys.exit()
print("Connecting to device %s" % (select))
if role == "source":
chan = device.CreateChannel(app_path, "reliable")
else:
chan = device.CreateChannel(app_path, "any")
print(chan)
enter_mainloop()