bluez/doc/mgmt-api.txt

1584 lines
41 KiB
Plaintext
Raw Blame History

This file contains ambiguous Unicode characters

This file contains Unicode characters that might be confused with other characters. If you think that this is intentional, you can safely ignore this warning. Use the Escape button to reveal them.

Bluetooth Management API
*************************
Copyright (C) 2008-2009 Marcel Holtmann <marcel@holtmann.org>
Packet Structures
=================
Commands:
0 4 8 12 16 22 24 28 31 35 39 43 47
+-------------------+-------------------+-------------------+
| Command Code | Controller Index | Parameter Length |
+-------------------+-------------------+-------------------+
| |
Events:
0 4 8 12 16 22 24 28 31 35 39 43 47
+-------------------+-------------------+-------------------+
| Event Code | Controller Index | Parameter Length |
+-------------------+-------------------+-------------------+
| |
All fields are in little-endian byte order (least significant byte first).
Controller Index can have a special value <non-controller> to indicate that
command or event is not related to any controller. Possible values:
<controller id> 0x0000 to 0xFFFE
<non-controller> 0xFFFF
Error Codes
===========
The following values have been defined for use with the Command Status
and Command Complete events:
0x00 Success
0x01 Unknown Command
0x02 Not Connected
0x03 Failed
0x04 Connect Failed
0x05 Authentication Failed
0x06 Not Paired
0x07 No Resources
0x08 Timeout
0x09 Already Connected
0x0A Busy
0x0B Rejected
0x0C Not Supported
0x0D Invalid Parameters
0x0E Disconnected
0x0F Not Powered
0x10 Cancelled
0x11 Invalid Index
Read Management Version Information Command
===========================================
Command Code: 0x0001
Controller Index: <non-controller>
Command Parameters:
Return Parameters: Version (1 Octets)
Revision (2 Octets)
This command returns the Management version and revision.
Besides, being informational the information can be used to
determine whether certain behavior has changed or bugs fixed
when interacting with the kernel.
This command generates a Command Complete event on success or
a Command Status event on failure.
Read Management Supported Commands Command
==========================================
Command Code: 0x0002
Controller Index: <non-controller>
Command Parameters:
Return Parameters: Num_Of_Commands (2 Octets)
Num_Of_Events (2 Octets)
Command1 (2 Octets)
Command2 (2 Octets)
...
Event1 (2 Octets)
Event2 (2 Octets)
...
This command returns the list of supported Management commands
and events.
The commands Read Management Version Information and Read
management Supported Commands are not included in this list.
Both commands are always supported and mandatory.
The events Command Status and Command Complete are not included
in this list. Both are implicit and mandatory.
This command generates a Command Complete event on success or
a Command Status event on failure.
Read Controller Index List Command
==================================
Command Code: 0x0003
Controller Index: <non-controller>
Command Parameters:
Return Parameters: Num_Controllers (2 Octets)
Controller_Index[i] (2 Octets)
This command returns the list of currently known controllers.
Controllers added or removed after calling this command can be
monitored using the Index Added and Index Removed events.
This command generates a Command Complete event on success or
a Command Status event on failure.
Read Controller Information Command
===================================
Command Code: 0x0004
Controller Index: <controller id>
Command Parameters:
Return Parameters: Address (6 Octets)
Bluetooth_Version (1 Octet)
Manufacturer (2 Octets)
Supported_Settings (4 Octets)
Current_Settings (4 Octets)
Class_Of_Device (3 Octets)
Name (249 Octets)
Short_Name (11 Octets)
This command is used to retreive the current state and basic
information of a controller. It is typically used right after
getting the response to the Read Controller Index List command
or an Index Added event.
If not short name is set the Short_Name parameter will be empty
(begin with a nul byte).
Current_Settings & Supported_Settings is a bitmask with
currently the following available bits:
1 Powered
2 Connectable
3 Fast Connectable
4 Discoverable
5 Pairable
6 Link Level Security (Sec. mode 3)
7 Secure Simple Pairing
8 Basic Rate/Enhanced Data Rate
9 High Speed
10 Low Energy
This command generates a Command Complete event on success or
a Command Status event on failure.
Possible errors: Invalid Parameters
Invalid Index
Set Powered Command
===================
Command Code: 0x0005
Controller Index: <controller id>
Command Parameters: Powered (1 Octet)
Return Parameters: Current_Settings (4 Octets)
This command is used to power on or off a controller. The
allowed Powered command parameter values are 0x00 and 0x01. All
other values will return Invalid Parameters.
If discoverable setting is activated with a timeout, then
switching the controller off will expire this timeout and
disable discoverable.
This command generates a Command Complete event on success or
a Command Status event on failure.
Possible errors: Busy
Invalid Parameters
Invalid Index
Set Discoverable Command
========================
Command Code: 0x0006
Controller Index: <controller id>
Command Parameters: Discoverable (1 Octet)
Timeout (2 Octets)
Return Parameters: Current_Settings (4 Octets)
This command is used to set the discoverable property of a
controller. The allowed Discoverable command parameter values
are 0x00 and 0x01. All other values will return Invalid Parameters.
Timeout is the time in seconds and is only meaningful when
Discoverable is set to 0x01. Providing a timeout with 0x00 will
return Invalid Parameters.
This command is only available for BR/EDR capable controllers
(e.g. not for single-mode LE ones). It will return Not Supported
otherwise.
This command can be used when the controller is not powered and
all settings will be programmed once powered.
However using a timeout when the controller is not powered will
return Not Powered error.
When switching discoverable on and the connectable setting is
off it will return Rejected error.
This command generates a Command Complete event on success or
a Command Status event on failure.
Possible errors: Busy
Rejected
Not Supported
Invalid Parameters
Not Powered
Invalid Index
Set Connectable Command
=======================
Command Code: 0x0007
Controller Index: <controller id>
Command Parameters: Connectable (1 Octet)
Return Parameters: Current_Settings (4 Octets)
This command is used to set the connectable property of a
controller. The allowed Connectable command parameter values are
0x00 and 0x01. All other values will return Invalid Parameters.
This command is only available for BR/EDR capable controllers
(e.g. not for single-mode LE ones). It will return Not Supported
otherwise.
This command can be used when the controller is not powered and
all settings will be programmed once powered.
When switching connectable off, it will also switch off the
discoverable setting. Switching connectable back on will not
restore a previous discoverable. It will stay off and needs
to be manually switched back on.
When switching connectable off, it will expire a discoverable
setting with a timeout.
This command generates a Command Complete event on success or
a Command Status event on failure.
Possible errors: Busy
Not Supported
Invalid Parameters
Invalid Index
Set Fast Connectable Command
============================
Command Code: 0x0008
Controller Index: <controller id>
Command Parameters: Enable (1 Octet)
Return Parameters: Current_Settings (4 Octets)
This command is used to set the controller into a connectable
state where the page scan parameters have been set in a way to
favor faster connect times with the expense of higher power
consumption.
The allowed values of the Enable command parameter are 0x00 and
0x01. All other values will return Invalid Parameters.
This command is only available for BR/EDR capable controllers
(e.g. not for single-mode LE ones). It will return Not Supported
otherwise.
This command can only be used when the controller is powered on
and will return Not Powerd otherwise.
If connectable is not set, then this command will fail with
Rejected error.
This command generates a Command Complete event on success or
a Command Status event on failure.
Possible errors: Failed
Busy
Rejected
Not Supported
Invalid Parameters
Not Powered
Invalid Index
Set Pairable Command
====================
Command Code: 0x0009
Controller Index: <controller id>
Command Parameters: Pairable (1 Octet)
Return Parameters: Current_Settings (4 Octets)
This command is used to set the pairable property of an
controller. The allowed values for the Pairable command
parameter are 0x00 and 0x01. All other values will return
Invalid Parameters.
This command can be used when the controller is not powered and
all settings will be programmed once powered.
Turning pairable on will not automatically switch the controller
into connectable mode. That needs to be done separately.
The setting will be remembered during power down/up toggles.
This command generates a Command Complete event on success or
a Command Status event on failure.
Possible errors: Invalid Parameters
Invalid Index
Set Link Security Command
=========================
Command Code: 0x000A
Controller Index: <controller id>
Command Parameters: Link_Security (1 Octet)
Return Parameters: Current_Settings (4 Octets)
This command is used to either enable or disable link level
security for an controller (also known as Security Mode 3). The
allowed values for the Link_Security command parameter are 0x00
and 0x01. All other values will return Invalid Parameters.
This command is only available for BR/EDR capable controllers
(e.g. not for single-mode LE ones). It will return Not Supported
otherwise.
This command can be used when the controller is not powered and
all settings will be programmed once powered.
This command generates a Command Complete event on success or
a Command Status event on failure.
Possible errors: Busy
Not Supported
Invalid Parameters
Invalid Index
Set Secure Simple Pairing Command
=================================
Command Code: 0x000B
Controller Index: <controller id>
Command Parameters: Secure_Simple_Pairing (1 Octet)
Return Parameters: Current_Settings (4 Octets)
This command is used to enable/disable Secure Simple Pairing
support for a controller. The allowed values for the
Secure_Simple_Pairing command parameter are 0x00 and 0x01. All
other values will return Invalid Parameters.
This command is only available for BR/EDR capable controllers
supporting the core specification version 2.1 or greater
(e.g. not for single-mode LE controllers or pre-2.1 ones).
This command can be used when the controller is not powered and
all settings will be programmed once powered.
In case the controller does not support Secure Simple Pairing,
the command will fail regardless with Not Supported error.
This command generates a Command Complete event on success or
a Command Status event on failure.
Possible errors: Busy
Not Supported
Invalid Parameters
Invalid Index
Set High Speed Command
======================
Command Code: 0x000C
Controller Index: <controller id>
Command Parameters: High_Speed (1 Octet)
Return Parameters: Current_Settings (4 Octets)
This command is used to enable/disable Bluetooth High Speed
support for a controller. The allowed values for the High_Speed
command parameter are 0x00 and 0x01. All other values will
return Invalid Parameters.
This command is only available for BR/EDR capable controllers
(e.g. not for single-mode LE ones).
This command can be used when the controller is not powered and
all settings will be programmed once powered.
In case the kernel subsystem does not support High Speed, the
command will fail regardless with Not Supported error.
This command generates a Command Complete event on success or
a Command Status event on failure.
Possible errors: Not Supported
Invalid Parameters
Invalid Index
Set Low Energy Command
======================
Command Code: 0x000D
Controller Index: <controller id>
Command Parameters: Low_Energy (1 Octet)
Return Parameters: Current_Settings (4 Octets)
This command is used to enable/disable Low Energy support for a
controller. The allowed values of the Low_Energy command
parameter are 0x00 and 0x01. All other values will return
Invalid Parameters.
This command is only available for LE capable controllers and
will yield in a Not Supported error otherwise.
This command can be used when the controller is not powered and
all settings will be programmed once powered.
In case the kernel subsystem does not support Low Energy or the
controller does not either, the command will fail regardless.
This command generates a Command Complete event on success or
a Command Status event on failure.
Possible errors: Not Supported
Invalid Parameters
Invalid Index
Set Device Class
================
Command Code: 0x000E
Controller Index: <controller id>
Command Parameters: Major_Class (1 Octet)
Minor_Class (1 Octet)
Return Parameters: Class_Of_Device (3 Octets)
This command is used to set the major and minor device class for
BR/EDR capable controllers.
This command will also implicitly disable caching of pending CoD
and EIR updates.
This command is only available for BR/EDR capable controllers
(e.g. not for single-mode LE ones).
This command can be used when the controller is not powered and
all settings will be programmed once powered.
In case the controller is powered off, 0x000000 will be returned
for the class of device parameter. And after power on the new
value will be announced via class of device changed event.
This command generates a Command Complete event on success or
a Command Status event on failure.
Possible errors: Busy
Not Supported
Invalid Parameters
Invalid Index
Set Local Name Command
======================
Command Code: 0x000F
Controller Index: <controller id>
Command Parameters: Name (249 Octets)
Short_Name (11 Octets)
Return Parameters: Name (249 Octets)
Short_Name (11 Octets)
This command is used to set the local name of a controller. The
command parameters also include a short name which will be used
in case the full name doesn't fit within EIR/AD data.
The name parameters need to always end with a null byte (failure
to do so will cause the command to fail).
This command can be used when the controller is not powered and
all settings will be programmed once powered.
The values of name and short name will be remembered when
switching the controller off and back on again. So the name
and short name only have to be set once when a new controller
is found and will stay until removed.
This command generates a Command Complete event on success or
a Command Status event on failure.
Possible errors: Invalid Parameters
Invalid Index
Add UUID Command
================
Command Code: 0x0010
Controller Index: <controller id>
Command Parameters: UUID (16 Octets)
SVC_Hint (1 Octet)
Return Parameters: Class_Of_Device (3 Octets)
This command is used to add a UUID to be published in EIR
and/or AD data. The accompanied SVC_Hint parameter is used to
tell the kernel whether the service class bits of the Class of
Device value need modifying due to this UUID.
This command can be used when the controller is not powered and
all settings will be programmed once powered.
In case the controller is powered off, 0x000000 will be returned
for the class of device parameter. And after power on the new
value will be announced via class of device changed event.
This command generates a Command Complete event on success or
a Command Status event on failure.
Possible errors: Busy
Invalid Parameters
Invalid Index
Remove UUID Command
===================
Command Code: 0x0011
Controller Index: <controller id>
Command Parameters: UUID (16 Octets)
Return Parameters: Class_Of_Device (3 Octets)
This command is used to remove a UUID previously added using the
Add UUID command.
When the UUID parameter is an empty UUID (16 x 0x00), then all
previously loaded UUIDs will be removed.
This command can be used when the controller is not powered and
all settings will be programmed once powered.
In case the controller is powered off, 0x000000 will be returned
for the class of device parameter. And after power on the new
value will be announced via class of device changed event.
This command generates a Command Complete event on success or
a Command Status event on failure.
Possible errors: Busy
Invalid Parameters
Invalid Index
Load Link Keys Command
======================
Command Code: 0x0012
Controller Index: <controller id>
Command Parameters: Debug_Keys (1 Octet)
Key_Count (2 Octets)
Key1 {
Address (6 Octets)
Address_Type (1 Octet)
Key_Type (1 Octet)
Value (16 Octets)
PIN_Length (1 Octet)
}
Key2 { }
...
Return Parameters:
This command is used to feed the kernel with currently known
link keys. The command does not need to be called again upon the
receiption of new link key events since the kernel updates its
list automatically.
This command can be used when the controller is not powered.
This command generates a Command Complete event on success or
a Command Status event on failure.
Possible errors: Invalid Parameters
Invalid Index
Load Long Term Keys Command
===========================
Command Code: 0x0013
Controller Index: <controller id>
Command Parameters: Key Count (2 Octets)
Key1 {
Address (6 Octets)
Address_Type (1 Octet)
Authenticated (1 Octet)
Master (1 Octet)
Encryption Size (1 Octet)
Enc. Diversifier (2 Octets)
Random Number (8 Octets)
Value (16 Octets)
}
Key2 { }
...
Return Parameters:
This command is used to feed the kernel with currently known
(SMP) Long Term Keys. The command does not need to be called
again upon the receiption of new Long Term Key events since the
kernel updates its list automatically.
This command can be used when the controller is not powered.
This command generates a Command Complete event on success or
a Command Status event on failure.
Possible errors: Invalid Parameters
Invalid Index
Disconnect Command
==================
Command Code: 0x0014
Controller Index: <controller id>
Command Parameters: Address (6 Octets)
Address_Type (1 Octet)
Return Parameters: Address (6 Octets)
Address_Type (1 Octet)
This command is used to force the disconnection of a currently
connected device.
This command can only be used when the controller is powered.
This command generates a Command Complete event on success
or failure.
Possible errors: Not Connected
Busy
Invalid Parameters
Not Powered
Invalid Index
Get Connections Command
=======================
Command Code: 0x0015
Controller Index: <controller id>
Command Parameters:
Return Parameters: Connection_Count (2 Octets)
Address1 {
Address (6 Octets)
Address_Type (1 Octet)
}
Address2 { }
...
This command is used to retreive a list of currently connected
devices.
Possible values for the Address_Type parameter:
0 BR/EDR
1 LE Public
2 LE Random
This command can only be used when the controller is powered.
This command generates a Command Complete event on success or
a Command Status event on failure.
Possible errors: Invalid Parameters
Not Powered
Invalid Index
PIN Code Reply Command
=======================
Command Code: 0x0016
Controller Index: <controller id>
Command Parameters: Address (6 Octets)
Address_Type (1 Octet)
PIN_Length (1 Octet)
PIN_Code (16 Octets)
Return Parameters: Address (6 Octets)
Address_Type (1 Octet)
This command is used to respond to a PIN Code request event.
This command can only be used when the controller is powered.
This command generates a Command Complete event on success
or failure.
Possible errors: Not Connected
Invalid Parameters
Not Powered
Invalid Index
PIN Code Negative Reply Command
===============================
Command Code: 0x0017
Controller Index: <controller id>
Command Parameters: Address (6 Octets)
Address_Type (1 Octet)
Return Parameters: Address (6 Octets)
Address_Type (1 Octet)
This command is used to return a negative response to a PIN Code
Request event.
This command can only be used when the controller is powered.
This command generates a Command Complete event on success
or failure.
Possible errors: Not Connected
Invalid Parameters
Not Powered
Invalid Index
Set IO Capability Command
=========================
Command Code: 0x0018
Controller Index: <controller id>
Command Parameters: IO_Capability (1 Octet)
Return Parameters:
This command is used to set the IO Capability used for pairing.
The command accepts both SSP and SMP values. The KeyboardDisplay
SMP value (which doesn't exist for SSP will) automatically be
downgraded to DisplayYesNo by the kernel for SSP pairing events.
This command can be used when the controller is not powered.
This command generates a Command Complete event on success or
a Command Status event on failure.
Possible errors: Invalid Parameters
Invalid Index
Pair Device Command
===================
Command Code: 0x0019
Controller Index: <controller id>
Command Parameters: Address (6 Octets)
Address_Type (1 Octet)
IO_Capability (1 Octet)
Return Parameters: Address (6 Octets)
Address_Type (1 Octet)
This command is used to trigger pairing with a remote device.
The IO_Capability command parameter is used to temporarily (for
this pairing event only) override the global IO Capaility (set
using the Set IO Capability command).
Possible values for the Address_Type parameter:
0 BR/EDR
1 LE Public
2 LE Random
This command can only be used when the controller is powered.
This command generates a Command Complete event on success
or failure.
Possible errors: Connect Failed
Busy
Invalid Parameters
Not Powered
Invalid Index
Cancel Pair Device
==================
Command Code: 0x001A
Controller Index: <controller id>
Command Parameters: Address (6 Octets)
Address_Type (1 Octet)
Return Parameters: Address (6 Octets)
Address_Type (1 Octet)
The Address and Address_Type parameters should match what was
given to a preceding Pair Device command.
This command can only be used when the controller is powered.
This command generates a Command Complete event on success
or failure.
Possible errors: Invalid Parameters
Not Powered
Invalid Index
Unpair Device Command
=====================
Command Code: 0x001B
Controller Index: <controller id>
Command Parameters: Address (6 Octets)
Address_Type (1 Octet)
Disconnect (1 Octet)
Return Parameters: Address (6 Octets)
Address_Type (1 Octet)
Removes all keys associated with the remote device.
The Disconnect parameter tells the kernel whether to forcefully
disconnect any existing connections to the device. It should in
practice always be 1 except for some special GAP qualification
test-cases where a key removal without disconnecting is needed.
This command can only be used when the controller is powered.
This command generates a Command Complete event on success
or failure.
Possible errors: Not Paired
Invalid Parameters
Not Powered
Invalid Index
User Confirmation Reply Command
===============================
Command Code: 0x001C
Controller Index: <controller id>
Command Parameters: Address (6 Octets)
Address_Type (1 Octet)
Return Parameters: Address (6 Octets)
Address_Type (1 Octet)
This command is used to respond to a User Confirmation Request
event.
This command can only be used when the controller is powered.
This command generates a Command Complete event on success
or failure.
Possible errors: Not Connected
Invalid Parameters
Not Powered
Invalid Index
User Confirmation Negative Reply Command
========================================
Command Code: 0x001D
Controller Index: <controller id>
Command Parameters: Address (6 Octets)
Address_Type (1 Octet)
Return Parameters: Address (6 Octets)
Address_Type (1 Octet)
This command is used to return a negative response to a User
Confirmation Request event.
This command can only be used when the controller is powered.
This command generates a Command Complete event on success
or failure.
Possible errors: Not Connected
Invalid Parameters
Not Powered
Invalid Index
User Passkey Reply Command
==========================
Command Code: 0x001E
Controller Index: <controller id>
Command Parameters: Address (6 Octets)
Address_Type (1 Octet)
Passkey (4 Octets)
Return Parameters: Address (6 Octets)
Address_Type (1 Octet)
This command is used to respond to a User Confirmation Passkey
Request event.
This command can only be used when the controller is powered.
This command generates a Command Complete event on success
or failure.
Possible errors: Not Connected
Invalid Parameters
Not Powered
Invalid Index
User Passkey Negative Reply Command
===================================
Command Code: 0x001F
Controller Index: <controller id>
Command Parameters: Address (6 Octets)
Address_Type (1 Octet)
Return Parameters: Address (6 Octets)
Address_Type (1 Octet)
This command is used to return a negative response to a User
Passkey Request event.
This command can only be used when the controller is powered.
This command generates a Command Complete event on success
or failure.
Possible errors: Not Connected
Invalid Parameters
Not Powered
Invalid Index
Read Local Out Of Band Data Command
===================================
Command Code: 0x0020
Controller Index: <controller id>
Command Parameters:
Return Parameters: Hash (16 Octets)
Randomizer (16 Octets)
This command is used to read the local Out of Band data.
This command can only be used when the controller is powered.
This command generates a Command Complete event on success or
a Command Status event on failure.
Possible errors: Not Supported
Busy
Invalid Parameters
Not Powered
Invalid Index
Add Remote Out Of Band Data Command
===================================
Command Code: 0x0021
Controller Index: <controller id>
Command Parameters: Address (6 Octets)
Address_Type (1 Octet)
Hash (16 Octets)
Randomizer (16 Octets)
Return Parameters: Address (6 Octets)
Address_Type (1 Octet)
This command is used to provide Out of Band data for a remote
device.
Provided Out Of Band data is persistent over power down/up toggles.
This command generates a Command Complete event on success
or failure.
Possible errors: Failed
Invalid Parameters
Not Powered
Invalid Index
Remove Remote Out Of Band Data Command
======================================
Command Code: 0x0022
Controller Index: <controller id>
Command Parameters: Address (6 Octets)
Address_Type (1 Octet)
Return Parameters: Address (6 Octets)
Address_Type (1 Octet)
This command is used to remove data added using the Add Remote
Out Of Band Data command.
This command generates a Command Complete event on success
or failure.
Possible errors: Invalid Parameters
Not Powered
Invalid Index
Start Discovery Command
=======================
Command Code: 0x0023
Controller Index: <controller id>
Command Parameters: Address_Type (1 Octet)
Return Parameters: Address_Type (1 Octet)
This command is used to start the process of discovering remote
devices. A Device Found event will be sent for each discovered
device.
Possible values for the Address_Type parameter are a bit-wise or
of the following bits:
1 BR/EDR
2 LE Public
3 LE Random
By combining these e.g. the following values are possible:
1 BR/EDR
6 LE (public & random)
7 BR/EDR/LE (interleaved discovery)
This command can only be used when the controller is powered.
This command generates a Command Complete event on success
or failure.
Possible errors: Busy
Not Supported
Invalid Parameters
Not Powered
Invalid Index
Stop Discovery Command
======================
Command Code: 0x0024
Controller Index: <controller id>
Command Parameters: Address_Type (1 Octet)
Return Parameters: Address_Type (1 Octet)
This command is used to stop the discovery process started using
the Start Discovery command.
This command can only be used when the controller is powered.
This command generates a Command Complete event on success
or failure.
Possible errors: Rejected
Invalid Parameters
Invalid Index
Confirm Name Command
====================
Command Code: 0x0025
Controller Index: <controller id>
Command Parameters: Address (6 Octets)
Address_Type (1 Octet)
Name_Known (1 Octet)
Return Parameters: Address (6 Octets)
Address_Type (1 Octet)
This command is only valid during device discovery and is
expected for each Device Found event with the Confirm Name
flag set.
This command can only be used when the controller is powered.
This command generates a Command Complete event on success
or failure.
Possible errors: Failed
Invalid Parameters
Invalid Index
Block Device Command
====================
Command Code: 0x0026
Controller Index: <controller id>
Command Parameters: Address (6 Octets)
Address_Type (1 Octet)
Return Parameters: Address (6 Octets)
Address_Type (1 Octet)
This command is used to add a device to the list of devices
which should be blocked from being connect to the local
controller.
This command can be used when the controller is not powered.
This command generates a Command Complete event on success
or failure.
Possible errors: Failed
Invalid Parameters
Invalid Index
Unblock Device Command
======================
Command Code: 0x0027
Controller Index: <controller id>
Command Parameters: Address (6 Octets)
Address_Type (1 Octet)
Return Parameters: Address (6 Octets)
Address_Type (1 Octet)
This command is used to remove a device from the list of blocked
devices (where it was added to using the Block Device command).
This command can be used when the controller is not powered.
This command generates a Command Complete event on success
or failure.
Possible errors: Invalid Parameters
Invalid Index
Set Device ID Command
=====================
Command Code: 0x0028
Controller Index: <controller id>
Command Parameters: Source (2 Octets)
Vendor (2 Octets)
Product (2 Octets)
Version (2 Octets)
Return Parameters:
This command can be used when the controller is not powered and
all settings will be programmed once powered.
The Source parameter selects the organization that assigned the
Vendor parameter:
0x0000 Disable Device ID
0x0001 Bluetooth SIG
0x0002 USB Implementers Forum
The information are put into the EIR data. If the controller does
not support EIR or if SSP is disabled, this command will still
succeed. The information are stored for later use and will survive
toggling SSP on and off.
This command generates a Command Complete event on success or
a Command Status event on failure.
Possible errors: Invalid Parameters
Invalid Index
Command Complete Event
======================
Event Code 0x0001
Controller Index: <controller id> or <non-controller>
Event Parameters Command_Opcode (2 Octets)
Status (1 Octet)
Return_Parameters
This event is an indication that a command has completed. The
fixed set of parameters includes the opcode to identify the
command that completed as well as a status value to indicate
success or failure. The rest of the parameters are command
specific and documented in the section for each command
separately.
Command Status Event
====================
Event Code 0x0002
Controller Index: <controller id> or <non-controller>
Event Parameters Command_Opcode (2 Octets)
Status (1 Octet)
The command status event is used to indicate an early status for
a pending command. In the case that the status indicates failure
(anything else except success status) this also means that the
command has finished executing.
Controller Error Event
======================
Event Code 0x0003
Controller Index: <controller id>
Event Parameters Error_Code (1 Octet)
This event maps straight to the HCI Hardware Error event and is
used to indicate something wrong with the controller hardware.
Index Added Event
=================
Event Code 0x0004
Controller Index: <controller id>
Event Parameters
This event indicates that a new controller has been added to the
system. It is usually followed by a Read Controller Information
command.
Index Removed Event
===================
Event Code 0x0005
Controller Index: <controller id>
Event Parameters
This event indicates that a controller has been removed from the
system.
New Settings Event
==================
Event Code 0x0006
Controller Index: <controller id>
Event Parameters: Current_Settings (4 Octets)
This event indicates that one or more of the settings for a
controller has changed.
Class Of Device Changed Event
=============================
Event Code 0x0007
Controller Index: <controller id>
Event Parameters: Class_Of_Device (3 Octets)
This event indicates that the Class of Device value for the
controller has changed. When the controller is powered off the
Class of Device value will always be reported as zero.
Local Name Changed Event
========================
Event Code 0x0008
Controller Index <controller id>
Event Parameters Name (249 Octets)
Short_Name (11 Octets)
This event indicates that the local name of the controller has
changed.
New Link Key Event
==================
Event Code 0x0009
Controller Index: <controller id>
Event Parametersa Store_Hint (1 Octet)
Key {
Address (6 Octets)
Address_Type (1 Octet)
Key_Type (1 Octet)
Value (16 Octets)
PIN_Length (1 Octet)
}
This event indicates that a new link key has bee generated for a
remote device. The Store_Hint parameter indicates whether the
host is expected to store the key persistently or not (e.g. this
would not be set if the authentication requirement was "No
Bonding").
New Long Term Key Event
=======================
Event Code 0x000A
Controller Index <controller id>
Event Parameters Store_Hint (1 Octet)
Key {
Address (6 Octets)
Address_Type (1 Octet)
Authenticated (1 Octet)
Master (1 Octet)
Encryption Size (1 Octet)
Enc. Diversifier (2 Octets)
Random Number (8 Octets)
Value (16 Octets)
}
This event indicates that a new long term key has bee generated
for a remote device. The Store_Hint parameter indicates whether
the host is expected to store the key persistently or not (e.g.
this would not be set if the authentication requirement was "No
Bonding").
Device Connected Event
======================
Event Code 0x000B
Controller Index: <controller id>
Event Parameters Address (6 Octets)
Address_Type (1 Octet)
Flags (4 Octets)
EIR_Data_Length (2 Octets)
EIR_Data (0-65535 Octets)
Possible values for the Address_Type parameter:
0 BR/EDR
1 LE Public
2 LE Random
The following bits are defined for the Flags parameter:
0 Reserved (not in use)
1 Legacy Pairing
This event indicates that a successful baseband connection has
been created to the remote device.
Device Disconnected Event
=========================
Event Code 0x000C
Controller Index: <controller id>
Event Parameters Address (6 Octets)
Address_Type (1 Octet)
Reason (1 Octet)
This event indicates that the baseband connection was lost to a
remote device.
Possible values for the Address_Type parameter:
0 BR/EDR
1 LE Public
2 LE Random
Possible values for the Reason parameter:
0 Unspecified
1 Connection timeout
2 Connection terminated by local host
3 Connection terminated by remote host
Note that the local/remote distinction just determines which side
terminated the low-level connection, regardless of the
disconnection of the higher-level profiles.
This can sometimes be misleading and thus must be used with care.
For example, some hardware combinations would report a locally
initiated disconnection even if the user turned Bluetooth off in
the remote side.
Connect Failed Event
====================
Event Code 0x000D
Controller Index: <controller id>
Event Parameters Address (6 Octets)
Address_Type (1 Octet)
Status (1 Octet)
This event indicates that a connection attempt failed to a
remote device.
Possible values for the Address_Type parameter:
0 BR/EDR
1 LE Public
2 LE Random
PIN Code Request Event
======================
Event Code 0x000E
Controller Index: <controller id>
Event Parameters Address (6 Octets)
Address_Type (1 Octet)
Secure (1 Octet)
This event is used to request a PIN Code reply from user space.
The reply should either be returned using the PIN Code Reply or
the PIN Code Negative Reply command.
Secure: 0x01 secure PIN code required
0x00 secure PIN code not required
User Confirmation Request Event
===============================
Event Code 0x000F
Controller Index: <controller id>
Event Parameters Address (6 Octets)
Address_Type (1 Octet)
Confirm_Hint (1 Octet)
Value (4 Octets)
This event is used to request a user confirmation request from
user space. If the Confirm_Hint parameter value is 0x01 this
means that a simple "Yes/No" confirmation should be presented to
the user instead of a full numerical confirmation (in which case
the parameter value will be 0x00).
User space should respond to this command either using the User
Confirmation Reply or the User Confirmation Negative Reply
command.
User Passkey Request Event
==========================
Event Code 0x0010
Controller Index: <controller id>
Event Parameters Address (6 Octets)
Address_Type (1 Octet)
This event is used to request a passkey from user space. The
response to this event should either be the User Passkey Reply
command or the User Passkey Negative Reply command.
Authentication Failed Event
===========================
Event Code 0x0011
Controller Index: <controller id>
Event Parameters Address (6 Octets)
Address_Type (1 Octet)
Status (1 Octet)
This event indicates that there was an authentication failure
with a remote device.
Device Found Event
==================
Event Code 0x0012
Controller Index <controller id>
Event Parameters Address (6 Octets)
Address_Type (1 Octet)
RSSI (1 Octet)
Flags (4 Octets)
EIR_Data_Length (2 Octets)
EIR_Data (0-65535 Octets)
This event indicates that a device was found during device
discovery.
Possible values for the Address_Type parameter:
0 BR/EDR
1 LE Public
2 LE Random
The following bits are defined for the Flags parameter:
0 Confirm name
1 Legacy Pairing
The Confirm name flag indicates that the kernel wants to know
whether user space knows the name for this device or not. If
this flag is set user space should respond to it using the
Confirm Name command.
The Legacy Pairing flag indicates that Legacy Pairing is likely
to occur when pairing with this device. An application could use
this information to optimize the pairing process by locally
pre-generating a PIN code and thereby eliminate the risk of
local input timeout when pairing. Note that there is a risk of
false-positives for this flag so user space should be able to
handle getting something else as a PIN Request when pairing.
Discovering Event
=================
Event Code 0x0013
Controller Index <controller id>
Event Parameters Address_Type (1 Octet)
Discovering (1 Octet)
This event indicates that the controller has started discovering
devices. This discovering state can come and go multiple times
between a StartDiscover and a StopDiscovery command.
The valid values for the Discovering parameter are 0x01
(enabled) and 0x00 (disabled).
Device Blocked Event
====================
Event Code 0x0014
Controller Index <controller id>
Event Parameters Address (6 Octets)
Address_Type (1 Octet)
This event indicates that a device has been blocked using the
Block Device command. The event will only be sent to Management
sockets other than the one through which the command was sent.
Device Unblocked Event
======================
Event Code 0x0015
Controller Index <controller id>
Event Parameters Address (6 Octets)
Address_Type (1 Octet)
This event indicates that a device has been unblocked using the
Unblock Device command. The event will only be sent to
Management sockets other than the one through which the command
was sent.
Device Unpaired Event
=====================
Event Code 0x0016
Controller Index <controller id>
Event Parameters Address (6 Octets)
Address_Type (1 Octet)
This event indicates that a device has been unpaired (i.e. all
its keys have been removed from the kernel) using the Unpair
Device command. The event will only be sent to Management
sockets other than the one through which the Unpair Device
command was sent.
Passkey Notify Event
====================
Event Code 0x0017
Controller Index <controller id>
Event Parameters Address (6 Octets)
Address_Type (1 Octet)
Passkey (4 Octets)
Entered (1 Octet)
This event is used to request passkey notification to the user.
Unlike the other authentication events it does not need
responding to using any Management command.
The Passkey parameter indicates the passkey to be shown to the
user whereas the Entered parameter indicates how many characters
the user has entered on the remote side.