bluez/test/test-heartrate
Petri Gynther 7adf8d09b4 test: Python import cleanup
Some test scripts use "from gi.repository import GObject" whereas others
use "import gobject". gi.repository is not always available on embedded
systems, so convert all instances to this format:

try:
  from gi.repository import GObject
except ImportError:
  import gobject as GObject

Also, sort the imports in this order: system, dbus, gobject, bluezutils
2014-01-18 00:38:39 -08:00

109 lines
2.7 KiB
Python
Executable File

#!/usr/bin/python
from __future__ import absolute_import, print_function, unicode_literals
'''
Heart Rate Monitor test script
'''
from optparse import OptionParser, make_option
import sys
import dbus
import dbus.service
import dbus.mainloop.glib
try:
from gi.repository import GObject
except ImportError:
import gobject as GObject
import bluezutils
BUS_NAME = 'org.bluez'
HEARTRATE_MANAGER_INTERFACE = 'org.bluez.HeartRateManager1'
HEARTRATE_WATCHER_INTERFACE = 'org.bluez.HeartRateWatcher1'
HEARTRATE_INTERFACE = 'org.bluez.HeartRate1'
class Watcher(dbus.service.Object):
@dbus.service.method(HEARTRATE_WATCHER_INTERFACE,
in_signature="oa{sv}", out_signature="")
def MeasurementReceived(self, device, measure):
print("Measurement received from %s" % device)
print("Value: ", measure["Value"])
if "Energy" in measure:
print("Energy: ", measure["Energy"])
if "Contact" in measure:
print("Contact: ", measure["Contact"])
if "Interval" in measure:
for i in measure["Interval"]:
print("Interval: ", i)
if __name__ == "__main__":
dbus.mainloop.glib.DBusGMainLoop(set_as_default=True)
bus = dbus.SystemBus()
option_list = [
make_option("-i", "--adapter", action="store",
type="string", dest="adapter"),
make_option("-b", "--device", action="store",
type="string", dest="address"),
]
parser = OptionParser(option_list=option_list)
(options, args) = parser.parse_args()
if not options.address:
print("Usage: %s [-i <adapter>] -b <bdaddr> [cmd]" % (sys.argv[0]))
print("Possible commands:")
print("\tReset")
sys.exit(1)
managed_objects = bluezutils.get_managed_objects()
adapter = bluezutils.find_adapter_in_objects(managed_objects,
options.adapter)
adapter_path = adapter.object_path
heartrateManager = dbus.Interface(bus.get_object(BUS_NAME,
adapter_path), HEARTRATE_MANAGER_INTERFACE)
path = "/test/watcher"
heartrateManager.RegisterWatcher(path)
device = bluezutils.find_device_in_objects(managed_objects,
options.address,
options.adapter)
device_path = device.object_path
heartrate = dbus.Interface(bus.get_object(BUS_NAME, device_path),
HEARTRATE_INTERFACE)
watcher = Watcher(bus, path)
dev_prop = dbus.Interface(bus.get_object(BUS_NAME, device_path),
"org.freedesktop.DBus.Properties")
properties = dev_prop.GetAll(HEARTRATE_INTERFACE)
if "Location" in properties:
print("Sensor location: %s" % properties["Location"])
else:
print("Sensor location is not supported")
if len(args) > 0:
if args[0] == "Reset":
reset_sup = properties["ResetSupported"]
if reset_sup:
heartrate.Reset()
else:
print("Reset not supported")
sys.exit(1)
else:
print("unknown command")
sys.exit(1)
mainloop = GObject.MainLoop()
mainloop.run()