mirror of
https://git.kernel.org/pub/scm/bluetooth/bluez.git
synced 2024-12-10 20:44:16 +08:00
67dab2d2ae
The method is now deprecated and thus the replacement utility library should be used in the test scripts.
93 lines
2.4 KiB
Python
Executable File
93 lines
2.4 KiB
Python
Executable File
#!/usr/bin/python
|
|
|
|
from __future__ import absolute_import, print_function, unicode_literals
|
|
|
|
'''
|
|
Thermometer test script
|
|
'''
|
|
|
|
import gobject
|
|
|
|
import sys
|
|
import dbus
|
|
import dbus.service
|
|
import dbus.mainloop.glib
|
|
from optparse import OptionParser, make_option
|
|
import bluezutils
|
|
|
|
class Watcher(dbus.service.Object):
|
|
@dbus.service.method("org.bluez.ThermometerWatcher",
|
|
in_signature="oa{sv}", out_signature="")
|
|
def MeasurementReceived(self, device, measure):
|
|
print("%s measurement received from %s" % (measure["Measurement"], device))
|
|
print("Exponent: ", measure["Exponent"])
|
|
print("Mantissa: ", measure["Mantissa"])
|
|
print("Unit: ", measure["Unit"])
|
|
|
|
if "Time" in measure:
|
|
print("Time: ", measure["Time"])
|
|
|
|
if "Type" in measure:
|
|
print("Type: ", measure["Type"])
|
|
|
|
def properties_changed(interface, changed, invalidated):
|
|
if interface != "org.bluez.Thermometer":
|
|
return
|
|
for name, value in changed.iteritems():
|
|
print("Property %s changed: %s" % (name, str(value)))
|
|
|
|
if __name__ == "__main__":
|
|
dbus.mainloop.glib.DBusGMainLoop(set_as_default=True)
|
|
|
|
bus = dbus.SystemBus()
|
|
|
|
option_list = [
|
|
make_option("-i", "--adapter", action="store",
|
|
type="string", dest="adapter"),
|
|
make_option("-b", "--device", action="store",
|
|
type="string", dest="address"),
|
|
]
|
|
|
|
parser = OptionParser(option_list=option_list)
|
|
|
|
(options, args) = parser.parse_args()
|
|
|
|
if not options.address:
|
|
print("Usage: %s [-i <adapter>] -b <bdaddr> [command]" % (sys.argv[0]))
|
|
print("Possible commands:")
|
|
print("\tEnableIntermediateMeasurement")
|
|
sys.exit(1)
|
|
|
|
managed_objects = bluezutils.get_managed_objects()
|
|
adapter = bluezutils.find_adapter_in_objects(managed_objects,
|
|
options.adapter)
|
|
adapter_path = adapter.object_path
|
|
|
|
thermometer_manager = dbus.Interface(bus.get_object("org.bluez",
|
|
adapter_path), "org.bluez.ThermometerManager")
|
|
|
|
device = bluezutils.find_device_in_objects(managed_objects,
|
|
options.address,
|
|
options.adapter)
|
|
device_path = device.object_path
|
|
|
|
bus.add_signal_receiver(properties_changed, bus_name="org.bluez",
|
|
path=device_path,
|
|
dbus_interface="org.freedesktop.DBus.Properties",
|
|
signal_name="PropertiesChanged")
|
|
|
|
path = "/test/watcher"
|
|
watcher = Watcher(bus, path)
|
|
|
|
thermometer_manager.RegisterWatcher(path)
|
|
|
|
if len(args) > 0:
|
|
if args[0] == "EnableIntermediateMeasurement":
|
|
thermometer_manager.EnableIntermediateMeasurement(path)
|
|
else:
|
|
print("unknown command")
|
|
sys.exit(1)
|
|
|
|
mainloop = gobject.MainLoop()
|
|