Bluetooth Management API ************************* Copyright (C) 2008-2009 Marcel Holtmann Overview ======== This document describes the format of data used for communicating with the kernel using a so-called Bluetooth Management sockets. These sockets are available starting with Linux kernel version 3.4 The following kernel versions introduced new commands, new events or important fixes to the Bluetooth Management API: Linux kernel v3.4 Version 1.0 Linux kernel v3.5 Version 1.1 Linux kernel v3.7 Version 1.2 Linux kernel v3.9 Version 1.3 Linux kernel v3.13 Version 1.4 Linux kernel v3.15 Version 1.5 Linux kernel v3.16 Version 1.6 Linux kernel v3.17 Version 1.7 Linux kernel v3.19 Version 1.8 Linux kernel v4.1 Version 1.9 Version 1.1 introduces Set Device ID command. Version 1.2 introduces Passkey Notify event. Version 1.3 does not introduce any new command or event. Version 1.4 introduces Set Advertising, Set BR/EDR, Set Static Address and Set Scan Parameters commands. The existing Set Discoverable command gained an extra setting for limited discoverable mode. The device name is now provided in the scan response data for Low Energy. Version 1.5 introduces Set Secure Connections, Set Debug Keys, Set Privacy and Load Identity Resolving Keys commands. It also introduces New Identity Resolving Key and New Signature Resolving Key events. Version 1.6 introduces Get Connection Information command. It also updates the Device Found event to combine advertising data and scan response data into a single event. Version 1.7 introduces Get Clock Information, Add Device, Remove Device, Load Connection Parameters, Read Unconfigured Index List, Read Controller Configuration Information, Set External Configuration and Set Public Address commands. It also introduces Device Added, Device Removed, New Connection Parameter, Unconfigured Index Added, Unconfigured Index Removed and New Configuration Options events. The existing Set Debug Keys command gained an extra setting for enabling SSP debug mode. Version 1.8 introduces Start Service Discovery command. It also adds new Long Term Key types for LE Secure Connection feature. Version 1.9 introduces Read Local Out Of Band Extended, Data, Read Extended Controller Index List, Read Advertising Features, Add Advertising and Remove Advertising commands. It also introduces Extended Index Added, Extended Index Removed, Local Out Of Band Extended Data Updated, Advertising Added and Advertising Removed events. The existing Set Advertising command gained an extra setting for enabling undirected connectable advertising. It provides support for a new static address setting and allows the usage of Set Fast Connectable when controller is powered off. Example ======= The Bluetooth management sockets can be created by setting the hci_channel member of struct sockaddr_hci to HCI_CHANNEL_CONTROL (3) when creating a raw HCI socket. In C the needed code would look something like the following: int mgmt_create(void) { struct sockaddr_hci addr; int fd; fd = socket(PF_BLUETOOTH, SOCK_RAW | SOCK_CLOEXEC | SOCK_NONBLOCK, BTPROTO_HCI); if (fd < 0) return -errno; memset(&addr, 0, sizeof(addr)); addr.hci_family = AF_BLUETOOTH; addr.hci_dev = HCI_DEV_NONE; addr.hci_channel = HCI_CHANNEL_CONTROL; if (bind(fd, (struct sockaddr *) &addr, sizeof(addr)) < 0) { int err = -errno; close(fd); return err; } return fd; } The process creating the mgmt socket is required to have the CAP_NET_ADMIN capability (e.g. root would have this). Packet Structures ================= Commands: 0 4 8 12 16 22 24 28 31 35 39 43 47 +-------------------+-------------------+-------------------+ | Command Code | Controller Index | Parameter Length | +-------------------+-------------------+-------------------+ | | Events: 0 4 8 12 16 22 24 28 31 35 39 43 47 +-------------------+-------------------+-------------------+ | Event Code | Controller Index | Parameter Length | +-------------------+-------------------+-------------------+ | | All fields are in little-endian byte order (least significant byte first). Controller Index can have a special value to indicate that command or event is not related to any controller. Possible values: 0x0000 to 0xFFFE 0xFFFF Error Codes =========== The following values have been defined for use with the Command Status and Command Complete events: 0x00 Success 0x01 Unknown Command 0x02 Not Connected 0x03 Failed 0x04 Connect Failed 0x05 Authentication Failed 0x06 Not Paired 0x07 No Resources 0x08 Timeout 0x09 Already Connected 0x0A Busy 0x0B Rejected 0x0C Not Supported 0x0D Invalid Parameters 0x0E Disconnected 0x0F Not Powered 0x10 Cancelled 0x11 Invalid Index 0x12 RFKilled 0x13 Already Paired 0x14 Permission Denied As a general rule all commands generate the events as specified below, however invalid lengths or unknown commands will always generate a Command Status response (with Unknown Command or Invalid Parameters status). Sending a command with an invalid Controller Index value will also always generate a Command Status event with the Invalid Index status code. Read Management Version Information Command =========================================== Command Code: 0x0001 Controller Index: Command Parameters: Return Parameters: Version (1 Octets) Revision (2 Octets) This command returns the Management version and revision. Besides, being informational the information can be used to determine whether certain behavior has changed or bugs fixed when interacting with the kernel. This command generates a Command Complete event on success or a Command Status event on failure. Read Management Supported Commands Command ========================================== Command Code: 0x0002 Controller Index: Command Parameters: Return Parameters: Num_Of_Commands (2 Octets) Num_Of_Events (2 Octets) Command1 (2 Octets) Command2 (2 Octets) ... Event1 (2 Octets) Event2 (2 Octets) ... This command returns the list of supported Management commands and events. The commands Read Management Version Information and Read management Supported Commands are not included in this list. Both commands are always supported and mandatory. The events Command Status and Command Complete are not included in this list. Both are implicit and mandatory. This command generates a Command Complete event on success or a Command Status event on failure. Read Controller Index List Command ================================== Command Code: 0x0003 Controller Index: Command Parameters: Return Parameters: Num_Controllers (2 Octets) Controller_Index[i] (2 Octets) This command returns the list of currently known controllers. Controllers added or removed after calling this command can be monitored using the Index Added and Index Removed events. This command generates a Command Complete event on success or a Command Status event on failure. Read Controller Information Command =================================== Command Code: 0x0004 Controller Index: Command Parameters: Return Parameters: Address (6 Octets) Bluetooth_Version (1 Octet) Manufacturer (2 Octets) Supported_Settings (4 Octets) Current_Settings (4 Octets) Class_Of_Device (3 Octets) Name (249 Octets) Short_Name (11 Octets) This command is used to retreive the current state and basic information of a controller. It is typically used right after getting the response to the Read Controller Index List command or an Index Added event. The Address parameter describes the controllers public address and it can be expected that it is set. However in case of single mode Low Energy only controllers it can be 00:00:00:00:00:00. To power on the controller in this case, it is required to configure a static address using Set Static Address command first. If the public address is set, then it will be used as identity address for the controller. If no public address is available, then the configured static address will be used as identity address. In the case of a dual-mode controller with public address that is configured as Low Energy only device (BR/EDR switched off), the static address is used when set and public address otherwise. If no short name is set the Short_Name parameter will be empty (begin with a nul byte). Current_Settings and Supported_Settings is a bitmask with currently the following available bits: 0 Powered 1 Connectable 2 Fast Connectable 3 Discoverable 4 Bondable 5 Link Level Security (Sec. mode 3) 6 Secure Simple Pairing 7 Basic Rate/Enhanced Data Rate 8 High Speed 9 Low Energy 10 Advertising 11 Secure Connections 12 Debug Keys 13 Privacy 14 Controller Configuration 15 Static Address This command generates a Command Complete event on success or a Command Status event on failure. Possible errors: Invalid Parameters Invalid Index Set Powered Command =================== Command Code: 0x0005 Controller Index: Command Parameters: Powered (1 Octet) Return Parameters: Current_Settings (4 Octets) This command is used to power on or off a controller. The allowed Powered command parameter values are 0x00 and 0x01. All other values will return Invalid Parameters. If discoverable setting is activated with a timeout, then switching the controller off will expire this timeout and disable discoverable. Settings programmed via Set Advertising and Add/Remove Advertising while the controller was powered off will be activated when powering the controller on. Switching the controller off will permanently cancel and remove all advertising instances with a timeout set, i.e. time limited advertising instances are not being remembered across power cycles. Advertising Removed events will be issued accordingly. This command generates a Command Complete event on success or a Command Status event on failure. Possible errors: Busy Invalid Parameters Invalid Index Set Discoverable Command ======================== Command Code: 0x0006 Controller Index: Command Parameters: Discoverable (1 Octet) Timeout (2 Octets) Return Parameters: Current_Settings (4 Octets) This command is used to set the discoverable property of a controller. The allowed Discoverable command parameter values are 0x00, 0x01 and 0x02. All other values will return Invalid Parameters. Timeout is the time in seconds and is only meaningful when Discoverable is set to 0x01 or 0x02. Providing a timeout with 0x00 return Invalid Parameters. For 0x02, the timeout value is required. The value 0x00 disables discoverable, the value 0x01 enables general discoverable and the value 0x02 enables limited discoverable. This command is only available for BR/EDR capable controllers (e.g. not for single-mode LE ones). It will return Not Supported otherwise. This command can be used when the controller is not powered and all settings will be programmed once powered. However using a timeout when the controller is not powered will return Not Powered error. When switching discoverable on and the connectable setting is off it will return Rejected error. This command generates a Command Complete event on success or a Command Status event on failure. Possible errors: Busy Rejected Not Supported Invalid Parameters Not Powered Invalid Index Set Connectable Command ======================= Command Code: 0x0007 Controller Index: Command Parameters: Connectable (1 Octet) Return Parameters: Current_Settings (4 Octets) This command is used to set the connectable property of a controller. The allowed Connectable command parameter values are 0x00 and 0x01. All other values will return Invalid Parameters. This command is available for BR/EDR, LE-only and also dual mode controllers. For BR/EDR is changes the page scan setting and for LE controllers it changes the advertising type. For dual mode controllers it affects both settings. For LE capable controllers the connectable setting takes affect when advertising is enabled (peripheral) or when directed advertising events are received (central). This command can be used when the controller is not powered and all settings will be programmed once powered. When switching connectable off, it will also switch off the discoverable setting. Switching connectable back on will not restore a previous discoverable. It will stay off and needs to be manually switched back on. When switching connectable off, it will expire a discoverable setting with a timeout. This setting does not affect known devices from Add Device command. These devices are always allowed to connect. This command generates a Command Complete event on success or a Command Status event on failure. Possible errors: Busy Not Supported Invalid Parameters Invalid Index Set Fast Connectable Command ============================ Command Code: 0x0008 Controller Index: Command Parameters: Enable (1 Octet) Return Parameters: Current_Settings (4 Octets) This command is used to set the controller into a connectable state where the page scan parameters have been set in a way to favor faster connect times with the expense of higher power consumption. The allowed values of the Enable command parameter are 0x00 and 0x01. All other values will return Invalid Parameters. This command is only available for BR/EDR capable controllers (e.g. not for single-mode LE ones). It will return Not Supported otherwise. This command can be used when the controller is not powered and all settings will be programmed once powered. The setting will be remembered during power down/up toggles. This command generates a Command Complete event on success or a Command Status event on failure. Possible errors: Failed Busy Not Supported Invalid Parameters Invalid Index Set Bondable Command ==================== Command Code: 0x0009 Controller Index: Command Parameters: Bondable (1 Octet) Return Parameters: Current_Settings (4 Octets) This command is used to set the bondable property of an controller. The allowed values for the Bondable command parameter are 0x00 and 0x01. All other values will return Invalid Parameters. This command can be used when the controller is not powered and all settings will be programmed once powered. Turning bondable on will not automatically switch the controller into connectable mode. That needs to be done separately. The setting will be remembered during power down/up toggles. This command generates a Command Complete event on success or a Command Status event on failure. Possible errors: Invalid Parameters Invalid Index Set Link Security Command ========================= Command Code: 0x000A Controller Index: Command Parameters: Link_Security (1 Octet) Return Parameters: Current_Settings (4 Octets) This command is used to either enable or disable link level security for an controller (also known as Security Mode 3). The allowed values for the Link_Security command parameter are 0x00 and 0x01. All other values will return Invalid Parameters. This command is only available for BR/EDR capable controllers (e.g. not for single-mode LE ones). It will return Not Supported otherwise. This command can be used when the controller is not powered and all settings will be programmed once powered. This command generates a Command Complete event on success or a Command Status event on failure. Possible errors: Busy Not Supported Invalid Parameters Invalid Index Set Secure Simple Pairing Command ================================= Command Code: 0x000B Controller Index: Command Parameters: Secure_Simple_Pairing (1 Octet) Return Parameters: Current_Settings (4 Octets) This command is used to enable/disable Secure Simple Pairing support for a controller. The allowed values for the Secure_Simple_Pairing command parameter are 0x00 and 0x01. All other values will return Invalid Parameters. This command is only available for BR/EDR capable controllers supporting the core specification version 2.1 or greater (e.g. not for single-mode LE controllers or pre-2.1 ones). This command can be used when the controller is not powered and all settings will be programmed once powered. In case the controller does not support Secure Simple Pairing, the command will fail regardless with Not Supported error. This command generates a Command Complete event on success or a Command Status event on failure. Possible errors: Busy Not Supported Invalid Parameters Invalid Index Set High Speed Command ====================== Command Code: 0x000C Controller Index: Command Parameters: High_Speed (1 Octet) Return Parameters: Current_Settings (4 Octets) This command is used to enable/disable Bluetooth High Speed support for a controller. The allowed values for the High_Speed command parameter are 0x00 and 0x01. All other values will return Invalid Parameters. This command is only available for BR/EDR capable controllers (e.g. not for single-mode LE ones). This command can be used when the controller is not powered and all settings will be programmed once powered. To enable High Speed support, it is required that Secure Simple Pairing support is enabled first. High Speed support is not possible for connections without Secure Simple Pairing. When switching Secure Simple Pairing off, the support for High Speed will be switched off as well. Switching Secure Simple Pairing back on, will not re-enable High Speed support. That needs to be done manually. This command generates a Command Complete event on success or a Command Status event on failure. Possible errors: Not Supported Invalid Parameters Invalid Index Set Low Energy Command ====================== Command Code: 0x000D Controller Index: Command Parameters: Low_Energy (1 Octet) Return Parameters: Current_Settings (4 Octets) This command is used to enable/disable Low Energy support for a controller. The allowed values of the Low_Energy command parameter are 0x00 and 0x01. All other values will return Invalid Parameters. This command is only available for LE capable controllers and will yield in a Not Supported error otherwise. This command can be used when the controller is not powered and all settings will be programmed once powered. In case the kernel subsystem does not support Low Energy or the controller does not either, the command will fail regardless. Disabling LE support will permanently disable and remove all advertising instances configured with the Add Advertising command. Advertising Removed events will be issued accordingly. This command generates a Command Complete event on success or a Command Status event on failure. Possible errors: Busy Not Supported Invalid Parameters Invalid Index Set Device Class ================ Command Code: 0x000E Controller Index: Command Parameters: Major_Class (1 Octet) Minor_Class (1 Octet) Return Parameters: Class_Of_Device (3 Octets) This command is used to set the major and minor device class for BR/EDR capable controllers. This command will also implicitly disable caching of pending CoD and EIR updates. This command is only available for BR/EDR capable controllers (e.g. not for single-mode LE ones). This command can be used when the controller is not powered and all settings will be programmed once powered. In case the controller is powered off, 0x000000 will be returned for the class of device parameter. And after power on the new value will be announced via class of device changed event. This command generates a Command Complete event on success or a Command Status event on failure. Possible errors: Busy Not Supported Invalid Parameters Invalid Index Set Local Name Command ====================== Command Code: 0x000F Controller Index: Command Parameters: Name (249 Octets) Short_Name (11 Octets) Return Parameters: Name (249 Octets) Short_Name (11 Octets) This command is used to set the local name of a controller. The command parameters also include a short name which will be used in case the full name doesn't fit within EIR/AD data. The name parameters need to always end with a null byte (failure to do so will cause the command to fail). This command can be used when the controller is not powered and all settings will be programmed once powered. The values of name and short name will be remembered when switching the controller off and back on again. So the name and short name only have to be set once when a new controller is found and will stay until removed. This command generates a Command Complete event on success or a Command Status event on failure. Possible errors: Invalid Parameters Invalid Index Add UUID Command ================ Command Code: 0x0010 Controller Index: Command Parameters: UUID (16 Octets) SVC_Hint (1 Octet) Return Parameters: Class_Of_Device (3 Octets) This command is used to add a UUID to be published in EIR data. The accompanied SVC_Hint parameter is used to tell the kernel whether the service class bits of the Class of Device value need modifying due to this UUID. This command can be used when the controller is not powered and all settings will be programmed once powered. In case the controller is powered off, 0x000000 will be returned for the class of device parameter. And after power on the new value will be announced via class of device changed event. This command generates a Command Complete event on success or a Command Status event on failure. Possible errors: Busy Invalid Parameters Invalid Index Remove UUID Command =================== Command Code: 0x0011 Controller Index: Command Parameters: UUID (16 Octets) Return Parameters: Class_Of_Device (3 Octets) This command is used to remove a UUID previously added using the Add UUID command. When the UUID parameter is an empty UUID (16 x 0x00), then all previously loaded UUIDs will be removed. This command can be used when the controller is not powered and all settings will be programmed once powered. In case the controller is powered off, 0x000000 will be returned for the class of device parameter. And after power on the new value will be announced via class of device changed event. This command generates a Command Complete event on success or a Command Status event on failure. Possible errors: Busy Invalid Parameters Invalid Index Load Link Keys Command ====================== Command Code: 0x0012 Controller Index: Command Parameters: Debug_Keys (1 Octet) Key_Count (2 Octets) Key1 { Address (6 Octets) Address_Type (1 Octet) Key_Type (1 Octet) Value (16 Octets) PIN_Length (1 Octet) } Key2 { } ... Return Parameters: This command is used to feed the kernel with currently known link keys. The command does not need to be called again upon the receiption of New Link Key events since the kernel updates its list automatically. The Debug_Keys parameter is used to tell the kernel whether to accept the usage of debug keys or not. The allowed values for this parameter are 0x00 and 0x01. All other values will return an Invalid Parameters response. Usage of the Debug_Keys parameter is deprecated and has been replaced with the Set Debug Keys command. When setting the Debug_Keys option via Load Link Keys command it has the same affect as setting it via Set Debug Keys and applies to all keys in the system. Possible values for the Address_Type parameter: 0 BR/EDR 1 Reserved (not in use) 2 Reserved (not in use) Public and random LE addresses are not valid and will be rejected. Currently defined Key_Type values are: 0x00 Combination key 0x01 Local Unit key 0x02 Remote Unit key 0x03 Debug Combination key 0x04 Unauthenticated Combination key from P-192 0x05 Authenticated Combination key from P-192 0x06 Changed Combination key 0x07 Unauthenticated Combination key from P-256 0x08 Authenticated Combination key from P-256 This command can be used when the controller is not powered. This command generates a Command Complete event on success or a Command Status event on failure. Possible errors: Invalid Parameters Invalid Index Load Long Term Keys Command =========================== Command Code: 0x0013 Controller Index: Command Parameters: Key_Count (2 Octets) Key1 { Address (6 Octets) Address_Type (1 Octet) Key_Type (1 Octet) Master (1 Octet) Encryption_Size (1 Octet) Encryption_Diversifier (2 Octets) Random_Number (8 Octets) Value (16 Octets) } Key2 { } ... Return Parameters: This command is used to feed the kernel with currently known (SMP) Long Term Keys. The command does not need to be called again upon the receiption of New Long Term Key events since the kernel updates its list automatically. Possible values for the Address_Type parameter: 0 Reserved (not in use) 1 LE Public 2 LE Random The provided Address and Address_Type are the identity of a device. So either its public address or static random address. Unresolvable random addresses and resolvable random addresses are not valid and will be rejected. Currently defined Key_Type values are: 0x00 Unauthenticated key 0x01 Authenticated key This command can be used when the controller is not powered. This command generates a Command Complete event on success or a Command Status event on failure. Possible errors: Invalid Parameters Invalid Index Disconnect Command ================== Command Code: 0x0014 Controller Index: Command Parameters: Address (6 Octets) Address_Type (1 Octet) Return Parameters: Address (6 Octets) Address_Type (1 Octet) This command is used to force the disconnection of a currently connected device. Possible values for the Address_Type parameter: 0 BR/EDR 1 LE Public 2 LE Random This command can only be used when the controller is powered. This command generates a Command Complete event on success or failure. Possible errors: Not Connected Busy Invalid Parameters Not Powered Invalid Index Get Connections Command ======================= Command Code: 0x0015 Controller Index: Command Parameters: Return Parameters: Connection_Count (2 Octets) Address1 { Address (6 Octets) Address_Type (1 Octet) } Address2 { } ... This command is used to retreive a list of currently connected devices. Possible values for the Address_Type parameter: 0 BR/EDR 1 LE Public 2 LE Random For devices using resolvable random addresses with a known identity resolving key, the Address and Address_Type will contain the identity information. This command can only be used when the controller is powered. This command generates a Command Complete event on success or a Command Status event on failure. Possible errors: Invalid Parameters Not Powered Invalid Index PIN Code Reply Command ======================= Command Code: 0x0016 Controller Index: Command Parameters: Address (6 Octets) Address_Type (1 Octet) PIN_Length (1 Octet) PIN_Code (16 Octets) Return Parameters: Address (6 Octets) Address_Type (1 Octet) This command is used to respond to a PIN Code request event. Possible values for the Address_Type parameter: 0 BR/EDR 1 LE Public 2 LE Random This command can only be used when the controller is powered. This command generates a Command Complete event on success or failure. Possible errors: Not Connected Invalid Parameters Not Powered Invalid Index PIN Code Negative Reply Command =============================== Command Code: 0x0017 Controller Index: Command Parameters: Address (6 Octets) Address_Type (1 Octet) Return Parameters: Address (6 Octets) Address_Type (1 Octet) This command is used to return a negative response to a PIN Code Request event. Possible values for the Address_Type parameter: 0 BR/EDR 1 LE Public 2 LE Random This command can only be used when the controller is powered. This command generates a Command Complete event on success or failure. Possible errors: Not Connected Invalid Parameters Not Powered Invalid Index Set IO Capability Command ========================= Command Code: 0x0018 Controller Index: Command Parameters: IO_Capability (1 Octet) Return Parameters: This command is used to set the IO Capability used for pairing. The command accepts both SSP and SMP values. Possible values for the IO_Capability parameter: 0 DisplayOnly 1 DisplayYesNo 2 KeyboardOnly 3 NoInputNoOutput 4 KeyboardDisplay Passing a value 4 (KeyboardDisplay) will cause the kernel to convert it to 1 (DisplayYesNo) in the case of a BR/EDR connection (as KeyboardDisplay is specific to SMP). This command can be used when the controller is not powered. This command generates a Command Complete event on success or a Command Status event on failure. Possible errors: Invalid Parameters Invalid Index Pair Device Command =================== Command Code: 0x0019 Controller Index: Command Parameters: Address (6 Octets) Address_Type (1 Octet) IO_Capability (1 Octet) Return Parameters: Address (6 Octets) Address_Type (1 Octet) This command is used to trigger pairing with a remote device. The IO_Capability command parameter is used to temporarily (for this pairing event only) override the global IO Capaility (set using the Set IO Capability command). Possible values for the Address_Type parameter: 0 BR/EDR 1 LE Public 2 LE Random Possible values for the IO_Capability parameter: 0 DisplayOnly 1 DisplayYesNo 2 KeyboardOnly 3 NoInputNoOutput 4 KeyboardDisplay Passing a value 4 (KeyboardDisplay) will cause the kernel to convert it to 1 (DisplayYesNo) in the case of a BR/EDR connection (as KeyboardDisplay is specific to SMP). The Address and Address_Type of the return parameters will return the identity address if known. In case of resolvable random address given as command parameters and the remote provides an identity resolving key, the return parameters will provide the resolved address. To allow tracking of which resolvable random address changed into which identity address, the New Identity Resolving Key event will be send before receiving Command Complete event for this command. This command can only be used when the controller is powered. This command generates a Command Complete event on success or failure. Reject status is used when requested transport is not enabled. Not Supported status is used if controller is not capable with requested transport. Possible errors: Rejected Not Supported Connect Failed Busy Invalid Parameters Not Powered Invalid Index Already Paired Cancel Pair Device Command ========================== Command Code: 0x001A Controller Index: Command Parameters: Address (6 Octets) Address_Type (1 Octet) Return Parameters: Address (6 Octets) Address_Type (1 Octet) The Address and Address_Type parameters should match what was given to a preceding Pair Device command. Possible values for the Address_Type parameter: 0 BR/EDR 1 LE Public 2 LE Random This command can only be used when the controller is powered. This command generates a Command Complete event on success or failure. Possible errors: Invalid Parameters Not Powered Invalid Index Unpair Device Command ===================== Command Code: 0x001B Controller Index: Command Parameters: Address (6 Octets) Address_Type (1 Octet) Disconnect (1 Octet) Return Parameters: Address (6 Octets) Address_Type (1 Octet) Removes all keys associated with the remote device. Possible values for the Address_Type parameter: 0 BR/EDR 1 LE Public 2 LE Random The Disconnect parameter tells the kernel whether to forcefully disconnect any existing connections to the device. It should in practice always be 1 except for some special GAP qualification test-cases where a key removal without disconnecting is needed. When unpairing a device its link key, long term key and if provided identity resolving key will be purged. For devices using resolvable random addresses where the identity resolving key was available, after this command they will now no longer be resolved. The device will essentially become private again. This command can only be used when the controller is powered. This command generates a Command Complete event on success or failure. Possible errors: Not Paired Invalid Parameters Not Powered Invalid Index User Confirmation Reply Command =============================== Command Code: 0x001C Controller Index: Command Parameters: Address (6 Octets) Address_Type (1 Octet) Return Parameters: Address (6 Octets) Address_Type (1 Octet) This command is used to respond to a User Confirmation Request event. Possible values for the Address_Type parameter: 0 BR/EDR 1 LE Public 2 LE Random This command can only be used when the controller is powered. This command generates a Command Complete event on success or failure. Possible errors: Not Connected Invalid Parameters Not Powered Invalid Index User Confirmation Negative Reply Command ======================================== Command Code: 0x001D Controller Index: Command Parameters: Address (6 Octets) Address_Type (1 Octet) Return Parameters: Address (6 Octets) Address_Type (1 Octet) This command is used to return a negative response to a User Confirmation Request event. Possible values for the Address_Type parameter: 0 BR/EDR 1 LE Public 2 LE Random This command can only be used when the controller is powered. This command generates a Command Complete event on success or failure. Possible errors: Not Connected Invalid Parameters Not Powered Invalid Index User Passkey Reply Command ========================== Command Code: 0x001E Controller Index: Command Parameters: Address (6 Octets) Address_Type (1 Octet) Passkey (4 Octets) Return Parameters: Address (6 Octets) Address_Type (1 Octet) This command is used to respond to a User Confirmation Passkey Request event. Possible values for the Address_Type parameter: 0 BR/EDR 1 LE Public 2 LE Random This command can only be used when the controller is powered. This command generates a Command Complete event on success or failure. Possible errors: Not Connected Invalid Parameters Not Powered Invalid Index User Passkey Negative Reply Command =================================== Command Code: 0x001F Controller Index: Command Parameters: Address (6 Octets) Address_Type (1 Octet) Return Parameters: Address (6 Octets) Address_Type (1 Octet) This command is used to return a negative response to a User Passkey Request event. Possible values for the Address_Type parameter: 0 BR/EDR 1 LE Public 2 LE Random This command can only be used when the controller is powered. This command generates a Command Complete event on success or failure. Possible errors: Not Connected Invalid Parameters Not Powered Invalid Index Read Local Out Of Band Data Command =================================== Command Code: 0x0020 Controller Index: Command Parameters: Return Parameters: Hash_192 (16 Octets) Randomizer_192 (16 Octets) Hash_256 (16 Octets, Optional) Randomizer_256 (16 Octets, Optional) This command is used to read the local Out of Band data. This command can only be used when the controller is powered. If Secure Connections support is enabled, then this command will return P-192 versions of hash and randomizer as well as P-256 versions of both. Values returned by this command become invalid when the controller is powered down. After each power-cycle it is required to call this command again to get updated values. This command generates a Command Complete event on success or a Command Status event on failure. Possible errors: Not Supported Busy Invalid Parameters Not Powered Invalid Index Add Remote Out Of Band Data Command =================================== Command Code: 0x0021 Controller Index: Command Parameters: Address (6 Octets) Address_Type (1 Octet) Hash_192 (16 Octets) Randomizer_192 (16 Octets) Hash_256 (16 Octets, Optional) Randomizer_256 (16 Octets, Optional) Return Parameters: Address (6 Octets) Address_Type (1 Octet) This command is used to provide Out of Band data for a remote device. Possible values for the Address_Type parameter: 0 BR/EDR 1 LE Public 2 LE Random Provided Out Of Band data is persistent over power down/up toggles. This command also accept optional P-256 versions of hash and randomizer. If they are not provided, then they are set to zero value. The P-256 versions of both can also be provided when the support for Secure Connections is not enabled. However in that case they will never be used. To only provide the P-256 versions of hash and randomizer, it is valid to leave both P-192 fields as zero values. If Secure Connections is disabled, then of course this is the same as not providing any data at all. When providing data for remote LE devices, then the Hash_192 and and Randomizer_192 fields are not used and shell be set to zero. The Hash_256 and Randomizer_256 fields can be used for LE secure connections Out Of Band data. If only LE secure connections data is provided the Hash_P192 and Randomizer_P192 fields can be set to zero. Currently there is no support for providing the Security Manager TK Value for LE legacy pairing. If Secure Connections Only mode has been enabled, then providing Hash_P192 and Randomizer_P192 is not allowed. They are required to be set to zero values. This command can be used when the controller is not powered and all settings will be programmed once powered. This command generates a Command Complete event on success or failure. Possible errors: Failed Invalid Parameters Not Powered Invalid Index Remove Remote Out Of Band Data Command ====================================== Command Code: 0x0022 Controller Index: Command Parameters: Address (6 Octets) Address_Type (1 Octet) Return Parameters: Address (6 Octets) Address_Type (1 Octet) This command is used to remove data added using the Add Remote Out Of Band Data command. Possible values for the Address_Type parameter: 0 BR/EDR 1 LE Public 2 LE Random When the Address parameter is 00:00:00:00:00:00, then all previously added data will be removed. This command can be used when the controller is not powered and all settings will be programmed once powered. This command generates a Command Complete event on success or failure. Possible errors: Invalid Parameters Not Powered Invalid Index Start Discovery Command ======================= Command Code: 0x0023 Controller Index: Command Parameters: Address_Type (1 Octet) Return Parameters: Address_Type (1 Octet) This command is used to start the process of discovering remote devices. A Device Found event will be sent for each discovered device. Possible values for the Address_Type parameter are a bit-wise or of the following bits: 0 BR/EDR 1 LE Public 2 LE Random By combining these e.g. the following values are possible: 1 BR/EDR 6 LE (public & random) 7 BR/EDR/LE (interleaved discovery) This command can only be used when the controller is powered. This command generates a Command Complete event on success or failure. Possible errors: Busy Not Supported Invalid Parameters Not Powered Invalid Index Stop Discovery Command ====================== Command Code: 0x0024 Controller Index: Command Parameters: Address_Type (1 Octet) Return Parameters: Address_Type (1 Octet) This command is used to stop the discovery process started using the Start Discovery command. This command can only be used when the controller is powered. This command generates a Command Complete event on success or failure. Possible errors: Rejected Invalid Parameters Invalid Index Confirm Name Command ==================== Command Code: 0x0025 Controller Index: Command Parameters: Address (6 Octets) Address_Type (1 Octet) Name_Known (1 Octet) Return Parameters: Address (6 Octets) Address_Type (1 Octet) This command is only valid during device discovery and is expected for each Device Found event with the Confirm Name flag set. Possible values for the Address_Type parameter: 0 BR/EDR 1 LE Public 2 LE Random The Name_Known parameter should be set to 0x01 if user space knows the name for the device and 0x00 if it doesn't. If set to 0x00 the kernel will perform a name resolving procedure for the device in question. This command can only be used when the controller is powered. This command generates a Command Complete event on success or failure. Possible errors: Failed Invalid Parameters Invalid Index Block Device Command ==================== Command Code: 0x0026 Controller Index: Command Parameters: Address (6 Octets) Address_Type (1 Octet) Return Parameters: Address (6 Octets) Address_Type (1 Octet) This command is used to add a device to the list of devices which should be blocked from being connect to the local controller. Possible values for the Address_Type parameter: 0 BR/EDR 1 LE Public 2 LE Random For Low Energy devices, the blocking of a device take presedence over auto-connection actions provided by Add Device. Blocked devices will not be auto-connected or even reported when found during background scanning. If the controller is connectable direct advertising from blocked devices will also be ignored. Connections created from advertising of the controller will be dropped if the device is blocked. This command can be used when the controller is not powered. This command generates a Command Complete event on success or failure. Possible errors: Failed Invalid Parameters Invalid Index Unblock Device Command ====================== Command Code: 0x0027 Controller Index: Command Parameters: Address (6 Octets) Address_Type (1 Octet) Return Parameters: Address (6 Octets) Address_Type (1 Octet) This command is used to remove a device from the list of blocked devices (where it was added to using the Block Device command). Possible values for the Address_Type parameter: 0 BR/EDR 1 LE Public 2 LE Random When the Address parameter is 00:00:00:00:00:00, then all previously blocked devices will be unblocked. This command can be used when the controller is not powered. This command generates a Command Complete event on success or failure. Possible errors: Invalid Parameters Invalid Index Set Device ID Command ===================== Command Code: 0x0028 Controller Index: Command Parameters: Source (2 Octets) Vendor (2 Octets) Product (2 Octets) Version (2 Octets) Return Parameters: This command can be used when the controller is not powered and all settings will be programmed once powered. The Source parameter selects the organization that assigned the Vendor parameter: 0x0000 Disable Device ID 0x0001 Bluetooth SIG 0x0002 USB Implementer’s Forum The information are put into the EIR data. If the controller does not support EIR or if SSP is disabled, this command will still succeed. The information are stored for later use and will survive toggling SSP on and off. This command generates a Command Complete event on success or a Command Status event on failure. Possible errors: Invalid Parameters Invalid Index Set Advertising Command ======================= Command Code: 0x0029 Controller Index: Command Parameters: Advertising (1 Octet) Return Parameters: Current_Settings (4 Octets) This command is used to enable LE advertising on a controller that supports it. The allowed values for the Advertising command parameter are 0x00, 0x01 and 0x02. All other values will return Invalid Parameters. The value 0x00 disables advertising, the value 0x01 enables advertising with considering of connectable setting and the value 0x02 enables advertising in connectable mode. Using value 0x01 means that when connectable setting is disabled, the advertising happens with undirected non-connectable advertising packets and a non-resovable random address is used. If connectable setting is enabled, then undirected connectable advertising packets and the identity address or resolvable private address are used. LE Devices configured via Add Device command with Action 0x01 have no effect when using Advertising value 0x01 since only the connectable setting is taken into account. To utilize undirected connectable advertising without changing the connectable setting, the value 0x02 can be utilized. It makes the device connectable via LE without the requirement for being connectable on BR/EDR (and/or LE). The value 0x02 should be the preferred mode of operation when implementing peripheral mode. Using this command will temporarily deactive any configuration made by the Add Advertising command. This command takes precedence. Once a Set Advertising command with value 0x00 is issued any previously made configurations via Add/Remove Advertising, including such changes made while Set Advertising was active, will be re- enabled. A pre-requisite is that LE is already enabled, otherwise this command will return a "rejected" response. This command generates a Command Complete event on success or a Command Status event on failure. Possible errors: Busy Rejected Not Supported Invalid Parameters Invalid Index Set BR/EDR Command ================== Command Code: 0x002A Controller Index: Command Parameters: BR/EDR (1 Octet) Return Parameters: Current_Settings (4 Octets) This command is used to enable or disable BR/EDR support on a dual-mode controller. The allowed values for the Advertising command parameter are 0x00 and 0x01. All other values will return Invalid Parameters. A pre-requisite is that LE is already enabled, otherwise this command will return a "rejected" response. Enabling BR/EDR can be done both when powered on and powered off, however disabling it can only be done when powered off (otherwise the command will again return "rejected"). Disabling BR/EDR will automatically disable all other BR/EDR related settings. This command generates a Command Complete event on success or a Command Status event on failure. Possible errors: Busy Rejected Not Supported Invalid Parameters Invalid Index Set Static Address Command ========================== Command Code: 0x002B Controller Index: Command Parameters: Address (6 Octets) Return Parameters: Current_Settings (4 Octets) This command allows for setting the static random address. It is only supported on controllers with LE support. The static random address is suppose to be valid for the lifetime of the controller or at least until the next power cycle. To ensure such behavior, setting of the address is limited to when the controller is powered off. The special BDADDR_ANY address (00:00:00:00:00:00) can be used to disable the static address. When a controller has a public address (which is required for all dual-mode controllers), this address is not used. If a dual-mode controller is configured as Low Energy only devices (BR/EDR has been switched off), then the static address is used. Only when the controller information reports BDADDR_ANY (00:00:00:00:00:00), it is required to configure a static address first. If privacy mode is enabled and the controller is single mode LE only without a public address, the static random address is used as identity address. The Static Address flag from the current settings can also be used to determine if the configured static address is in use or not. This command generates a Command Complete event on success or a Command Status event on failure. Possible errors: Rejected Not Supported Invalid Parameters Invalid Index Set Scan Parameters Command =========================== Command Code: 0x002C Controller Index: Command Parameters: Interval (2 Octets) Window (2 Octets) Return Parameters: This command allows for setting the Low Energy scan parameters used for connection establishment and passive scanning. It is only supported on controllers with LE support. This command generates a Command Complete event on success or a Command Status event on failure. Possible errors: Rejected Not Supported Invalid Parameters Invalid Index Set Secure Connections Command ============================== Command Code: 0x002D Controller Index: Command Parameters: Secure_Connections (1 Octet) Return Parameters: Current_Settings (4 Octets) This command is used to enable/disable Secure Connections support for a controller. The allowed values for the Secure_Connections command parameter are 0x00, 0x01 and 0x02. All other values will return Invalid Parameters. The value 0x00 disables Secure Connections, the value 0x01 enables Secure Connections and the value 0x02 enables Secure Connections Only mode. This command is only available for LE capable controllers as well as controllers supporting the core specification version 4.1 or greater. This command can be used when the controller is not powered and all settings will be programmed once powered. In case the controller does not support Secure Connections the command will fail regardless with Not Supported error. This command generates a Command Complete event on success or a Command Status event on failure. Possible errors: Busy Not Supported Invalid Parameters Invalid Index Set Debug Keys Command ====================== Command Code: 0x002E Controller Index: Command Parameters: Debug_Keys (1 Octet) Return Parameters: Current_Settings (4 Octets) This command is used to tell the kernel whether to accept the usage of debug keys or not. The allowed values for this parameter are 0x00, 0x01 and 0x02. All other values will return an Invalid Parameters response. With a value of 0x00 any generated debug key will be discarded as soon as the connection terminates. With a value of 0x01 generated debug keys will be kept and can be used for future connections. However debug keys are always marked as non persistent and should not be stored. This means a reboot or changing the value back to 0x00 will delete them. With a value of 0x02 generated debug keys will be kept and can be used for future connections. This has the same affect as with value 0x01. However in addition this value will also enter the controller mode to generate debug keys for each new pairing. Changing the value back to 0x01 or 0x00 will disable the controller mode for generating debug keys. This command generates a Command Complete event on success or a Command Status event on failure. Possible errors: Busy Not Supported Invalid Parameters Invalid Index Set Privacy Command =================== Command Code: 0x002F Controller Index: Command Parameters: Privacy (1 Octet) Identity_Resolving_Key (16 Octets) Return Parameters: Current_Settings (4 Octets) This command is used to enable Low Energy Privacy feature using resolvable private addresses. The value 0x00 disables privacy mode, the values 0x01 and 0x02 enable privacy mode. With value 0x01 the kernel will always use the privacy mode. This means resolvable private address is used when the controller is discoverable and also when pairing is initiated. With value 0x02 the kernel will use privacy mode with resolvable private address. In case the conroller is bondable and discoverable the identity address is used. Also when pairing is initiated, the connection will be established with the identity address. Exposing the identity address when bondable and discoverable or during initated pairing can be a privacy issue. For dual-mode controllers this can be neglected since its public address will be exposed over BR/EDR anyway. The benefit of exposing the identity address for pairing purposes is that it makes matching up devices with dual-mode topology during device discovery now possible. If the privacy value 0x02 is used, then also the GATT database should expose the Privacy Characteristic so that remote devices can determine if the privacy feature is in use or not. When the controller has a public address (mandatory for dual-mode controllers) it is used as identity address. In case the controller is single mode LE only without a public address, it is required to configure a static random andress first. The privacy mode can only be enabled when an identity address is available. The Identity_Resolving_Key is the local key assigned for the local resolvable private address. Possible errors: Busy Not Supported Invalid Parameters Invalid Index Load Identity Resolving Keys Command ==================================== Command Code: 0x0030 Controller Index: Command Parameters: Key_Count (2 Octets) Key1 { Address (6 Octets) Address_Type (1 Octet) Value (16 Octets) } Key2 { } ... Return Parameters: This command is used to feed the kernel with currently known identity resolving keys. The command does not need to be called again upon the receiption of New Identity Resolving Key events since the kernel updates its list automatically. Possible values for the Address_Type parameter: 0 Reserved (not in use) 1 LE Public 2 LE Random The provided Address and Address_Type are the identity of a device. So either its public address or static random address. Unresolvable random addresses and resolvable random addresses are not valid and will be rejected. This command can be used when the controller is not powered. This command generates a Command Complete event on success or a Command Status event on failure. Possible errors: Invalid Parameters Invalid Index Get Connection Information Command ================================== Command Code: 0x0031 Controller Index: Command Parameters: Address (6 Octets) Address_Type (1 Octet) Return Parameters: Address (6 Octets) Address_Type (1 Octet) RSSI (1 Octet) TX_Power (1 Octet) Max_TX_Power (1 Octet) This command is used to get connection information. Possible values for the Address_Type parameter: 0 BR/EDR 1 LE Public 2 LE Random TX_Power and Max_TX_Power can be set to 127 if values are invalid or unknown. A value of 127 for RSSI indicates that it is not available. This command generates a Command Complete event on success and on failure. In case of failure only Address and Address_Type fields are valid and values of remaining parameters are considered invalid and shall be ignored. Possible errors: Not Connected Not Powered Invalid Parameters Invalid Index Get Clock Information Command ============================= Command Code: 0x0032 Controller Index: Command Parameters: Address (6 Octets) Address_Type (1 Octet) Return Parameters: Address (6 Octets) Address_Type (1 Octet) Local_Clock (4 Octets) Piconet_Clock (4 Octets) Accuracy (2 Octets) This command is used to get local and piconet clock information. Possible values for the Address_Type parameter: 0 BR/EDR 1 Reserved (not in use) 2 Reserved (not in use) The Accuracy can be set to 0xffff which means the value is unknown. If the Address is set to 00:00:00:00:00:00, then only the Local_Clock field has a valid value. The Piconet_Clock and Accuracy fields are invalid and shall be ignored. This command generates a Command Complete event on success and on failure. In case of failure only Address and Address_Type fields are valid and values of remaining parameters are considered invalid and shall be ignored. Possible errors: Not Connected Not Powered Invalid Parameters Invalid Index Add Device Command ================== Command Code: 0x0033 Controller Index: Command Parameters: Address (6 Octets) Address_Type (1 Octet) Action (1 Octet) Return Parameters: Address (6 Octets) Address_Type (1 Octet) This command is used to add a device to the action list. The action list allows scanning for devices and enables incoming connections from known devices. Possible values for the Address_Type parameter: 0 BR/EDR 1 LE Public 2 LE Random Possible values for the Action parameter: 0 Background scan for device 1 Allow incoming connection 2 Auto-connect remote device With the Action 0, when the device is found, a new Device Found event will be send indicating this device is available. This action is only valid for LE Public and LE Random address types. With the Action 1, the device is allowed to connect. For BR/EDR address type this means an incoming connection. For LE Public and LE Random address types, a connection will be established to devices using directed advertising. If successful a Device Connected event will be send. With the Action 2, when the device is found, it will be connected and if successful a Device Connected event will be send. This action is only valid for LE Public and LE Random address types. When a device is blocked using Block Device command, then it is valid to add the device here, but all actions will be ignored until the device is unblocked. Devices added with Action 1 are allowed to connect even if the connectable setting is off. This acts as list of known trusted devices. This command can be used when the controller is not powered and all settings will be programmed once powered. This command generates a Command Complete event on success or failure. Possible errors: Failed Invalid Parameters Invalid Index Remove Device Command ===================== Command Code: 0x0034 Controller Index: Command Parameters: Address (6 Octets) Address_Type (1 Octet) Return Parameters: Address (6 Octets) Address_Type (1 Octet) This command is used to remove a device from the action list previously added by using the Add Device command. Possible values for the Address_Type parameter: 0 BR/EDR 1 LE Public 2 LE Random When the Address parameter is 00:00:00:00:00:00, then all previously added devices will be removed. This command can be used when the controller is not powered and all settings will be programmed once powered. This command generates a Command Complete event on success or failure. Possible errors: Invalid Parameters Invalid Index Load Connection Parameters Command ================================== Command Code: 0x0035 Controller Index: Command Parameters: Param_Count (2 Octets) Param1 { Address (6 Octets) Address_Type (1 Octet) Min_Connection_Interval (2 Octets) Max_Connection_Interval (2 Octes) Connection_Latency (2 Octets) Supervision_Timeout (2 Octets) } Param2 { } ... Return Parameters: This command is used to load connection parameters from several devices into kernel. Currently this is only supported on controllers with Low Energy support. Possible values for the Address_Type parameter: 0 Reserved (not in use) 1 LE Public 2 LE Random The provided Address and Address_Type are the identity of a device. So either its public address or static random address. The Min_Connection_Interval, Max_Connection_Interval, Connection_Latency and Supervision_Timeout parameters should be configured as described in Core 4.1 spec, Vol 2, 7.8.12. This command can be used when the controller is not powered. This command generates a Command Complete event on success or a Command Status event on failure. Possible errors: Invalid Parameters Invalid Index Not Supported Read Unconfigured Controller Index List Command =============================================== Command Code: 0x0036 Controller Index: Command Parameters: Return Parameters: Num_Controllers (2 Octets) Controller_Index[i] (2 Octets) This command returns the list of currently unconfigured controllers. Unconfigured controllers added after calling this command can be monitored using the Unconfigured Index Added event. An unconfigured controller can either move to a configured state by indicating Unconfigured Index Removed event followed by an Index Added event; or it can be removed from the system which would be indicated by the Unconfigured Index Removed event. Only controllers that require configuration will be listed with this command. A controller that is fully configured will not be listed even if it supports configuration changes. This command generates a Command Complete event on success or a Command Status event on failure. Read Controller Configuration Information Command ================================================= Command Code: 0x0037 Controller Index: Command Parameters: Return Parameters: Manufacturer (2 Octets) Supported_Options (4 Octets) Missing_Options (4 Octets) This command is used to retreive the supported configuration options of a controller and the missing configuration options. The missing options are required to be configured before the controller is considered fully configured and ready for standard operation. The command is typically used right after getting the response to Read Unconfigured Controller Index List command or Unconfigured Index Added event. Supported_Options and Missing_Options is a bitmask with currently the following available bits: 0 External configuration 1 Bluetooth public address configuration It is valid to call this command on controllers that do not require any configuration. It is possible that a fully configured controller offers additional support for configuration. For example a controller may contain a valid Bluetooth public device address, but also allows to configure it from the host stack. In this case the general support for configurations will be indicated by the Controller Configuration settings. For controllers where no configuration options are available that setting option will not be present. When all configurations have been completed and as a result the Missing_Options mask would become empty, then the now ready controller will be announced via Index Added event. This command generates a Command Complete event on success or a Command Status event on failure. Possible errors: Invalid Parameters Invalid Index Set External Configuration Command ================================== Command Code: 0x0038 Controller Index: Command Parameters: Configuration (1 Octet) Return Parameters: Missing_Options (4 Octets) This command allows to change external configuration option to indicate that a controller is now configured or unconfigured. The value 0x00 sets unconfigured state and the value 0x01 sets configured state of the controller. It is not mandatory that this configuration option is provided by a controller. If it is provided, the configuration has to happen externally using user channel operation or via vendor specific methods. Setting this option and when Missing_Options returns zero, this means that the controller will switch to configured state and it can be expected that it will be announced via Index Added event. Wrongly configured controllers might still cause an error when trying to power them via Set Powered commmand. This command generates a Command Complete event on success or a Command Status event on failure. Possible errors: Rejected Not Supported Invalid Parameters Invalid Index Set Public Address Command ========================== Command Code: 0x0039 Controller Index: Command Parameters: Address (6 Octets) Return Parameters: Missing_Options (4 Octets) This command allows configuration of public address. Since a vendor specific procedure is required, this command might not be supported by all controllers. Actually most likely only a handful embedded controllers will offer support for this command. When the support for Bluetooth public address configuration is indicated in the supported options mask, then this command can be used to configure the public address. It is only possible to configure the public address when the controller is powered off. For an unconfigured controller and when Missing_Options returns an empty mask, this means that a Index Added event for the now fully configured controller can be expected. For a fully configured controller, the current controller index will become invalid and an Unconfigured Index Removed event will be send. Once the address has been successfully changed an Index Added event will be send. There is no guarantee that the controller index stays the same. All previous configured parameters and settings are lost when this command succeeds. The controller has to be treated as new one. Use this command for a fully configured controller only when you really know what you are doing. This command generates a Command Complete event on success or a Command Status event on failure. Possible errors: Rejected Not Supported Invalid Parameters Invalid Index Start Service Discovery Command =============================== Command Code: 0x003a Controller Index: Command Parameters: Address_Type (1 Octet) RSSI_Threshold (1 Octet) UUID_Count (1 Octet) UUID[i] (16 Octets) Return Parameters: Address_Type (1 Octet) This command is used to start the process of discovering remote devices with a specific UUID. A Device Found event will be sent for each discovered device. Possible values for the Address_Type parameter are a bit-wise or of the following bits: 0 BR/EDR 1 LE Public 2 LE Random By combining these e.g. the following values are possible: 1 BR/EDR 6 LE (public & random) 7 BR/EDR/LE (interleaved discovery) The service discovery uses active scanning for Low Energy scanning and will search for UUID in both advertising data and scan response data. Found devices that have a RSSI value smaller than RSSI_Threshold are not reported via DeviceFound event. Setting a value of 127 will cause all devices to be reported. The list of UUIDs identifies a logical OR. Only one of the UUIDs have to match to cause a DeviceFound event. Providing an empty list of UUIDs with Num_UUID set to 0 which means that DeviceFound events are send out for all devices above the RSSI_Threshold. In case RSSI_Threshold is set to 127 and UUID_Count is 0, then this command behaves exactly the same as Start Discovery. When the discovery procedure starts the Discovery event will notify this similar to Start Discovery. This command can only be used when the controller is powered. This command generates a Command Complete event on success or failure. Possible errors: Busy Not Supported Invalid Parameters Not Powered Invalid Index Read Local Out Of Band Extended Data Command ============================================ Command Code: 0x003b Controller Index: Command Parameters: Address_Type (1 Octet) Return Parameters: Address_Type (1 Octet) EIR_Data_Length (2 Octets) EIR_Data (0-65535 Octets) This command is used to read the local Out of Band data information and provide them encoded as extended inquiry response information or advertising data. Possible values for the Address_Type parameter are a bit-wise or of the following bits: 0 BR/EDR 1 LE Public 2 LE Random By combining these e.g. the following values are possible: 1 BR/EDR 6 LE (public & random) 7 Reserved (not in use) For BR/EDR controller (Address_Type 1) the returned information will contain the following information: Class of Device Simple Pairing Hash C-192 (optional) Simple Pairing Randomizer R-192 (optional) Simple Pairing Hash C-256 (optional) Simple Pairing Randomizer R-256 (optional) Service Class UUID (optional) Bluetooth Local Name (optional) The Simple Pairing Hash C-256 and Simple Pairing Randomizer R-256 fields are only included when secure connections has been enabled. The Device Address (BD_ADDR) is not included in the EIR_Data and needs to be taken from controller information. For LE controller (Address_Type 6) the returned information will contain the following information: LE Bluetooth Device Address LE Role LE Secure Connections Confirmation Value (optional) LE Secure Connections Random Value (optional) Appearance (optional) Local Name (optional) Flags The LE Secure Connections Confirmation Value and LE Secure Connections Random Value fields are only included when secure connections has been enabled. The Security Manager TK Value from the Bluetooth specification can not be provided by this command. The Out Of Band information here are for asymmetric exchanges based on Diffie-Hellman key exchange. The Security Manager TK Value is a symmetric random number that has to be acquired and agreed upon differently. The returned information from BR/EDR controller and LE controller types are not related to each other. Once they have been used over an Out Of Band link, a new set of information shall be requested. When Secure Connections Only mode has been enabled, then the fields for Simple Pairing Hash C-192 and Simple Pairing Randomizer R-192 are not returned. Only the fields for the strong secure connections pairing are included. This command can only be used when the controller is powered. Values returned by this command become invalid when the controller is powered down. After each power-cycle it is required to call this command again to get updated information. This command generates a Command Complete event on success or a Command Status event on failure. Possible errors: Not Supported Busy Invalid Parameters Not Powered Invalid Index Read Extended Controller Index List Command =========================================== Command Code: 0x003c Controller Index: Command Parameters: Return Parameters: Num_Controllers (2 Octets) Controller_Index[i] (2 Octets) Controller_Type[i] (1 Octet) Controller_Bus[i] (1 Octet) This command returns the list of currently known controllers. It includes configured, unconfigured and alternate controllers. Controllers added or removed after calling this command can be be monitored using the Extended Index Added and Extended Index Removed events. The existing Index Added, Index Removed, Unconfigured Index Added and Unconfigured Index Removed are no longer sent after this command has been used at least once. Instead of calling Read Controller Index List and Read Unconfigured Controller Index List, this command combines all the information and can be used to retrieve the controller list. The Controller_Type parameter has these values: 0x00 Primary Controller (BR/EDR and/or LE) 0x01 Unconfigured Controller (BR/EDR and/or LE) 0x02 Alternate MAC/PHY Controller (AMP) The 0x00 and 0x01 types indiciate a primary BR/EDR and/or LE controller. The difference is just if they need extra configuration or if they are fully configured. Controllers in configured state will be listed as 0x00 and controllers in unconfigured state will be listed as 0x01. A controller that is fully configured and supports configuration changes will be listed as 0x00. Alternate MAC/PHY controllers will be listed as 0x02. They do not support the difference between configured and unconfigured state. The Controller_Bus parameter has these values: 0x00 Virtual 0x01 USB 0x02 PCMCIA 0x03 UART 0x04 RS232 0x05 PCI 0x06 SDIO Controllers marked as RAW only operation are currently not listed by this command. This command generates a Command Complete event on success or a Command Status event on failure. Read Advertising Features Command ================================= Command Code: 0x003d Controller Index: Command Parameters: Return Parameters: Supported_Flags (4 Octets) Max_Adv_Data_Len (1 Octet) Max_Scan_Rsp_Len (1 Octet) Max_Instances (1 Octet) Num_Instances (1 Octet) Instance[i] (1 Octet) This command is used to read the advertising features supported by the controller and stack. With the Supported_Flags field the possible values for the Flags field in Add Advertising command provided: 0 Switch into Connectable mode 1 Advertise as Discoverable 2 Advertise as Limited Discoverable 3 Add Flags field to Adv_Data 4 Add TX Power field to Adv_Data 5 Add Appearance field to Scan_Rsp 6 Add Local Name in Scan_Rsp The Flags bit 0 indicates support for connectable advertising and for switching to connectable advertising independent of the connectable global setting. When this flag is not supported, then the global connectable setting determines if undirected connectable, undirected scannable or undirected non-connectable advertising is used. It also determines the use of non-resolvable random address versus identity address or resolvable private address. The Flags bit 1 indicates support for advertising with discoverable mode enabled. Users of this flag will decrease the Max_Adv_Data_Len by 3 octets. In this case the advertising data flags are managed and added in front of the provided advertising data. The Flags bit 2 indicates support for advertising with limited discoverable mode enabled. Users of this flag will decrease the Max_Adv_Data_Len by 3 octets. In this case the advertising data flags are managed and added in front of the provided advertising data. The Flags bit 3 indicates support for automatically keeping the Flags field of the advertising data updated. Users of this flag will decrease the Max_Adv_Data_Len by 3 octets and need to keep that in mind. The Flags field will be added in front of the advertising data provided by the user. Note that with Flags bit 1 and Flags bit 2, this one will be implicitly used even if it is not marked as supported. The Flags bit 4 indicates support for automatically adding the TX Power value to the advertising data. Users of this flag will decrease the Max_Adv_Data_Len by 3 octets. The TX Power field will be added at the end of the user provided advertising data. If the controller does not support TX Power information, then this bit will not be set. The Flags bit 5 indicates support for automatically adding the Apperance value to the scan response data. Users of this flag will decrease the Max_Scan_Rsp_len by 4 octets. The Appearance field will be added in front of the scan response data provided by the user. If the appearance value is not supported, then this bit will not be set. The Flags bit 6 indicates support for automatically adding the Local Name value to the scan response data. This flag indicates an opportunistic approach for the Local Name. If enough space in the scan response data is available, it will be added. If the space is limited a short version or no name information. The Local Name will be added at the end of the scan response data. The valid range for Instance identifiers is 1-254. The value 0 is reserved for internal use and the value 255 is reserved for future extensions. However the Max_Instances value for indicating the number of supported Instances can be also 0 if the controller does not support any advertising. The Max_Adv_Data_Len and Max_Scan_Rsp_Len provides extra information about the maximum length of the data fields. For now this will always return the value 31. Different flags however might decrease the actual available length in these data fields. With Num_Instances and Instance array the current occupied Instance identifiers can be retrieved. This command generates a Command Complete event on success or a Command Status event on failure. Possible errors: Invalid Parameters Invalid Index Add Advertising Command ======================= Command Code: 0x003e Controller Index: Command Parameters: Instance (1 Octet) Flags (4 Octets) Duration (2 Octets) Timeout (2 Octets) Adv_Data_Len (1 Octet) Scan_Rsp_len (1 Octet) Adv_Data (0-255 Octets) Scan_Rsp (0-255 Octets) Return Parameters: Instance (1 Octet) This command is used to configure an advertising instance that can be used to switch a Bluetooth Low Energy controller into advertising mode. Added advertising information with this command will not be visible immediately if advertising is enabled via the Set Advertising command. The usage of the Set Advertising command takes precedence over this command. Instance information is stored and will be advertised once advertising via Set Advertising has been disabled. The Instance identifier is a value between 1 and the number of supported instances. The value 0 is reserved. With the Flags value the type of advertising is controlled and the following flags are defined: 0 Switch into Connectable mode 1 Advertise as Discoverable 2 Advertise as Limited Discoverable 3 Add Flags field to Adv_Data 4 Add TX Power field to Adv_Data 5 Add Appearance field to Scan_Rsp 6 Add Local Name in Scan_Rsp When the connectable flag is set, then the controller will use undirected connectable advertising. The value of the connectable setting can be overwritten this way. This is useful to switch a controller into connectable mode only for LE operation. This is similar to the mode 0x02 from the Set Advertising command. When the connectable flag is not set, then the controller will use advertising based on the connectable setting. When using non-connectable or scannable advertising, the controller will be programmed with a non-resolvable random address. When the system is connectable, then the identity address or resolvable private address will be used. Using the connectable flag is useful for peripheral mode support where BR/EDR (and/or LE) is controlled by Add Device. This allows making the peripheral connectable without having to interfere with the global connectable setting. If Scan_Rsp_Len is zero and connectable flag is not set and the global connectable setting is off, then non-connectable advertising is used. If Scan_Rsp_Len is larger than zero and connectable flag is not set and the global advertising is off, then scannable advertising is used. This small difference is supported to provide less air traffic for devices implementing broadcaster role. The Duration parameter configures the length of an Instance. The value is in seconds. A value of 0 indicates a default value is chosen for the Duration. The default is 2 seconds. If only one advertising Instance has been added, then the Duration value will be ignored. It only applies for the case where multiple Instances are configured. In that case every Instance will be available for the Duration time and after that it switches to the next one. This is a simple round-robin based approach. The Timeout parameter configures the life-time of an Instance. In case the value 0 is used it indicates no expiration time. If a timeout value is provided, then the advertising Instace will be automatically removed when the timeout passes. The value for the timeout is in seconds. Powering down a controller will invalidate all advertising Instances and it is not possible to add a new Instance with a timeout when the controller is powered down. When a Timeout is provided, then the Duration substracts from the actual Timeout value of that Instance. For example an Instance with Timeout of 5 and Duration of 2 will be scheduled exactly 3 times, twice with 2 seconds and once with one second. Other Instances have no influence on the Timeout. Re-adding an already existing instance (i.e. issuing the Add Advertising command with an Instance identifier of an existing instance) will update that instance's configuration. An instance being added or changed while another instance is being advertised will not be visible immediately but only when the new/changed instance is being scheduled by the round robin advertising algorithm. Changes to an instance that is currently being advertised will cancel that instance and switch to the next instance. The changes will be visible the next time the instance is scheduled for advertising. In case a single instance is active, this means that changes will be visible right away. A pre-requisite is that LE is already enabled, otherwise this command will return a "rejected" response. This command can be used when the controller is not powered and all settings will be programmed once powered. This command generates a Command Complete event on success or a Command Status event on failure. Possible errors: Failed Rejected Not Supported Invalid Parameters Invalid Index Remove Advertising Command ========================== Command Code: 0x003f Controller Index: Command Parameters: Instance (1 Octet) Return Parameters: Instance (1 Octet) This command is used to remove an advertising instance that can be used to switch a Bluetooth Low Energy controller into advertising mode. When the Instance parameter is zero, then all previously added advertising Instances will be removed. Removing advertising information with this command will not be visible as long as advertising is enabled via the Set Advertising command. The usage of the Set Advertising command takes precedence over this command. Changes to Instance information are stored and will be advertised once advertising via Set Advertising has been disabled. Removing an instance while it is being advertised will immediately cancel the instance, even when it has been advertised less then its configured Timeout or Duration. This command can be used when the controller is not powered and all settings will be programmed once powered. This command generates a Command Complete event on success or a Command Status event on failure. Possible errors: Invalid Parameters Invalid Index Start Limited Discovery Command =============================== Command Code: 0x0040 Controller Index: Command Parameters: Address_Type (1 Octet) Return Parameters: Address_Type (1 Octet) This command is used to start the process of discovering remote devices using the limited discovery procedure. A Device Found event will be sent for each discovered device. Possible values for the Address_Type parameter are a bit-wise or of the following bits: 0 BR/EDR 1 LE Public 2 LE Random By combining these e.g. the following values are possible: 1 BR/EDR 6 LE (public & random) 7 BR/EDR/LE (interleaved discovery) The limited discovery uses active scanning for Low Energy scanning and will search for devices with the limited discoverabilty flag configured. On BR/EDR it uses LIAC and filters on the limited discoverabilty flag of the class of device. When the discovery procedure starts the Discovery event will notify this similar to Start Discovery. This command can only be used when the controller is powered. This command generates a Command Complete event on success or failure. Possible errors: Busy Not Supported Invalid Parameters Not Powered Invalid Index Command Complete Event ====================== Event Code: 0x0001 Controller Index: or Event Parameters: Command_Opcode (2 Octets) Status (1 Octet) Return_Parameters This event is an indication that a command has completed. The fixed set of parameters includes the opcode to identify the command that completed as well as a status value to indicate success or failure. The rest of the parameters are command specific and documented in the section for each command separately. Command Status Event ==================== Event Code: 0x0002 Controller Index: or Event Parameters: Command_Opcode (2 Octets) Status (1 Octet) The command status event is used to indicate an early status for a pending command. In the case that the status indicates failure (anything else except success status) this also means that the command has finished executing. Controller Error Event ====================== Event Code: 0x0003 Controller Index: Event Parameters: Error_Code (1 Octet) This event maps straight to the HCI Hardware Error event and is used to indicate something wrong with the controller hardware. Index Added Event ================= Event Code: 0x0004 Controller Index: Event Parameters: This event indicates that a new controller has been added to the system. It is usually followed by a Read Controller Information command. Once the Read Extended Controller Index List command has been used at least once, the Extended Index Added event will be send instead of this one. Index Removed Event =================== Event Code: 0x0005 Controller Index: Event Parameters: This event indicates that a controller has been removed from the system. Once the Read Extended Controller Index List command has been used at least once, the Extended Index Removed event will be send instead of this one. New Settings Event ================== Event Code: 0x0006 Controller Index: Event Parameters: Current_Settings (4 Octets) This event indicates that one or more of the settings for a controller has changed. Class Of Device Changed Event ============================= Event Code: 0x0007 Controller Index: Event Parameters: Class_Of_Device (3 Octets) This event indicates that the Class of Device value for the controller has changed. When the controller is powered off the Class of Device value will always be reported as zero. Local Name Changed Event ======================== Event Code: 0x0008 Controller Index: Event Parameters: Name (249 Octets) Short_Name (11 Octets) This event indicates that the local name of the controller has changed. New Link Key Event ================== Event Code: 0x0009 Controller Index: Event Parameters: Store_Hint (1 Octet) Key { Address (6 Octets) Address_Type (1 Octet) Key_Type (1 Octet) Value (16 Octets) PIN_Length (1 Octet) } This event indicates that a new link key has bee generated for a remote device. The Store_Hint parameter indicates whether the host is expected to store the key persistently or not (e.g. this would not be set if the authentication requirement was "No Bonding"). Possible values for the Address_Type parameter: 0 BR/EDR 1 Reserved (not in use) 2 Reserved (not in use) Public and random LE addresses are not valid and will be rejected. Currently defined Key_Type values are: 0x00 Combination key 0x01 Local Unit key 0x02 Remote Unit key 0x03 Debug Combination key 0x04 Unauthenticated Combination key from P-192 0x05 Authenticated Combination key from P-192 0x06 Changed Combination key 0x07 Unauthenticated Combination key from P-256 0x08 Authenticated Combination key from P-256 Receiving this event indicates that a pairing procecure has been completed. New Long Term Key Event ======================= Event Code: 0x000A Controller Index: Event Parameters: Store_Hint (1 Octet) Key { Address (6 Octets) Address_Type (1 Octet) Key_Type (1 Octet) Master (1 Octet) Encryption Size (1 Octet) Enc. Diversifier (2 Octets) Random Number (8 Octets) Value (16 Octets) } This event indicates that a new long term key has been generated for a remote device. The Store_Hint parameter indicates whether the host is expected to store the key persistently or not (e.g. this would not be set if the authentication requirement was "No Bonding"). Possible values for the Address_Type parameter: 0 Reserved (not in use) 1 LE Public 2 LE Random The provided Address and Address_Type are the identity of a device. So either its public address or static random address. For unresolvable random addresses and resolvable random addresses without identity information and identity resolving key, the Store_Hint will be set to not store the long term key. Currently defined Key_Type values are: 0x00 Unauthenticated legacy key 0x01 Authenticated legacy key 0x02 Unauthenticated key from P-256 0x03 Authenticated key from P-256 0x04 Debug key from P-256 Receiving this event indicates that a pairing procecure has been completed. Device Connected Event ====================== Event Code: 0x000B Controller Index: Event Parameters: Address (6 Octets) Address_Type (1 Octet) Flags (4 Octets) EIR_Data_Length (2 Octets) EIR_Data (0-65535 Octets) This event indicates that a successful baseband connection has been created to the remote device. Possible values for the Address_Type parameter: 0 BR/EDR 1 LE Public 2 LE Random For devices using resolvable random addresses with a known identity resolving key, the Address and Address_Type will contain the identity information. It is possible that devices get connected via its resolvable random address and after New Identity Resolving Key event start using its identity. The following bits are defined for the Flags parameter: 0 Reserved (not in use) 1 Legacy Pairing 2 Reserved (not in use) Device Disconnected Event ========================= Event Code: 0x000C Controller Index: Event Parameters: Address (6 Octets) Address_Type (1 Octet) Reason (1 Octet) This event indicates that the baseband connection was lost to a remote device. Possible values for the Address_Type parameter: 0 BR/EDR 1 LE Public 2 LE Random For devices using resolvable random addresses with a known identity resolving key, the Address and Address_Type will contain the identity information. Possible values for the Reason parameter: 0 Unspecified 1 Connection timeout 2 Connection terminated by local host 3 Connection terminated by remote host Note that the local/remote distinction just determines which side terminated the low-level connection, regardless of the disconnection of the higher-level profiles. This can sometimes be misleading and thus must be used with care. For example, some hardware combinations would report a locally initiated disconnection even if the user turned Bluetooth off in the remote side. Connect Failed Event ==================== Event Code: 0x000D Controller Index: Event Parameters: Address (6 Octets) Address_Type (1 Octet) Status (1 Octet) This event indicates that a connection attempt failed to a remote device. Possible values for the Address_Type parameter: 0 BR/EDR 1 LE Public 2 LE Random For devices using resolvable random addresses with a known identity resolving key, the Address and Address_Type will contain the identity information. PIN Code Request Event ====================== Event Code: 0x000E Controller Index: Event Parameters: Address (6 Octets) Address_Type (1 Octet) Secure (1 Octet) This event is used to request a PIN Code reply from user space. The reply should either be returned using the PIN Code Reply or the PIN Code Negative Reply command. Possible values for the Address_Type parameter: 0 BR/EDR 1 LE Public 2 LE Random Secure: 0x01 secure PIN code required 0x00 secure PIN code not required User Confirmation Request Event =============================== Event Code: 0x000F Controller Index: Event Parameters: Address (6 Octets) Address_Type (1 Octet) Confirm_Hint (1 Octet) Value (4 Octets) This event is used to request a user confirmation request from user space. Possible values for the Address_Type parameter: 0 BR/EDR 1 LE Public 2 LE Random If the Confirm_Hint parameter value is 0x01 this means that a simple "Yes/No" confirmation should be presented to the user instead of a full numerical confirmation (in which case the parameter value will be 0x00). User space should respond to this command either using the User Confirmation Reply or the User Confirmation Negative Reply command. User Passkey Request Event ========================== Event Code: 0x0010 Controller Index: Event Parameters: Address (6 Octets) Address_Type (1 Octet) This event is used to request a passkey from user space. The response to this event should either be the User Passkey Reply command or the User Passkey Negative Reply command. Possible values for the Address_Type parameter: 0 BR/EDR 1 LE Public 2 LE Random Authentication Failed Event =========================== Event Code: 0x0011 Controller Index: Event Parameters: Address (6 Octets) Address_Type (1 Octet) Status (1 Octet) This event indicates that there was an authentication failure with a remote device. Possible values for the Address_Type parameter: 0 BR/EDR 1 LE Public 2 LE Random Device Found Event ================== Event Code: 0x0012 Controller Index: Event Parameters: Address (6 Octets) Address_Type (1 Octet) RSSI (1 Octet) Flags (4 Octets) EIR_Data_Length (2 Octets) EIR_Data (0-65535 Octets) This event indicates that a device was found during device discovery. Possible values for the Address_Type parameter: 0 BR/EDR 1 LE Public 2 LE Random The following bits are defined for the Flags parameter: 0 Confirm name 1 Legacy Pairing 2 Not Connectable For the RSSI field a value of 127 indicates that the RSSI is not available. That can happen with Bluetooth 1.1 and earlier controllers or with bad radio conditions. The Confirm name flag indicates that the kernel wants to know whether user space knows the name for this device or not. If this flag is set user space should respond to it using the Confirm Name command. The Legacy Pairing flag indicates that Legacy Pairing is likely to occur when pairing with this device. An application could use this information to optimize the pairing process by locally pre-generating a PIN code and thereby eliminate the risk of local input timeout when pairing. Note that there is a risk of false-positives for this flag so user space should be able to handle getting something else as a PIN Request when pairing. The Not Connectable flag indicates that the device will not accept any connections. This can be indicated by Low Energy devices that are in broadcaster role. Discovering Event ================= Event Code: 0x0013 Controller Index: Event Parameters: Address_Type (1 Octet) Discovering (1 Octet) This event indicates that the controller has started discovering devices. This discovering state can come and go multiple times between a Start Discovery and a Stop Discovery commands. The Start Service Discovery command will also trigger this event. The valid values for the Discovering parameter are 0x01 (enabled) and 0x00 (disabled). Device Blocked Event ==================== Event Code: 0x0014 Controller Index: Event Parameters: Address (6 Octets) Address_Type (1 Octet) This event indicates that a device has been blocked using the Block Device command. Possible values for the Address_Type parameter: 0 BR/EDR 1 LE Public 2 LE Random The event will only be sent to Management sockets other than the one through which the command was sent. Device Unblocked Event ====================== Event Code: 0x0015 Controller Index: Event Parameters: Address (6 Octets) Address_Type (1 Octet) This event indicates that a device has been unblocked using the Unblock Device command. Possible values for the Address_Type parameter: 0 BR/EDR 1 LE Public 2 LE Random The event will only be sent to Management sockets other than the one through which the command was sent. Device Unpaired Event ===================== Event Code: 0x0016 Controller Index: Event Parameters: Address (6 Octets) Address_Type (1 Octet) This event indicates that a device has been unpaired (i.e. all its keys have been removed from the kernel) using the Unpair Device command. Possible values for the Address_Type parameter: 0 BR/EDR 1 LE Public 2 LE Random For devices using resolvable random addresses with a known identity resolving key, the event paramters will contain the identity. After receiving this event, the device will become essentially private again. The event will only be sent to Management sockets other than the one through which the Unpair Device command was sent. Passkey Notify Event ==================== Event Code: 0x0017 Controller Index: Event Parameters: Address (6 Octets) Address_Type (1 Octet) Passkey (4 Octets) Entered (1 Octet) This event is used to request passkey notification to the user. Unlike the other authentication events it does not need responding to using any Management command. Possible values for the Address_Type parameter: 0 BR/EDR 1 LE Public 2 LE Random The Passkey parameter indicates the passkey to be shown to the user whereas the Entered parameter indicates how many characters the user has entered on the remote side. New Identity Resolving Key Event ================================ Event Code: 0x0018 Controller Index: Event Parameters: Store_Hint (1 Octet) Random_Address (6 Octets) Key { Address (6 Octets) Address_Type (1 Octet) Value (16 Octets) } This event indicates that a new identity resolving key has been generated for a remote device. The Store_Hint parameter indicates whether the host is expected to store the key persistently or not. The Random_Address provides the resolvable random address that was resolved into an identity. A value of 00:00:00:00:00:00 indicates that the identity resolving key was provided for a public address or static random address. Once this event has been send for a resolvable random address, all further events mapping this device will send out using the identity address information. This event also indicates that now the identity address should be used for commands instead of the resolvable random address. It is possible that some devices allow discovering via its identity address, but after pairing using resolvable private address only. In such a case Store_Hint will be 0x00 and the Random_Address will indicate 00:00:00:00:00:00. For these devices, the Privacy Characteristic of the remote GATT database should be consulted to decide if the identity resolving key must be stored persistently or not. Devices using Set Privacy command with the option 0x02 would be such type of device. Possible values for the Address_Type parameter: 0 Reserved (not in use) 1 LE Public 2 LE Random The provided Address and Address_Type are the identity of a device. So either its public address or static random address. New Signature Resolving Key Event ================================= Event Code: 0x0019 Controller Index: Event Parameters: Store_Hint (1 Octet) Key { Address (6 Octets) Address_Type (1 Octet) Type (1 Octet) Value (16 Octets) } This event indicates that a new signature resolving key has been generated for either the master or slave device. The Store_Hint parameter indicates whether the host is expected to store the key persistently or not. The Type parameter has the following possible values: 0x00 Unauthenticated local CSRK 0x01 Unauthenticated remote CSRK 0x02 Authenticated local CSRK 0x03 Authenticated remote CSRK The local keys are used for signing data to be sent to the remote device, whereas the remote keys are used to verify signatures received from the remote device. The local signature resolving key will be generated with each pairing request. Only after receiving this event with the Type indicating a local key is it possible to use ATT Signed Write procedures. Possible values for the Address_Type parameter: 0 Reserved (not in use) 1 LE Public 2 LE Random The provided Address and Address_Type are the identity of a device. So either its public address or static random address. Device Added Event ================== Event Code: 0x001a Controller Index: Event Parameters: Address (6 Octets) Address_Type (1 Octet) Action (1 Octet) This event indicates that a device has been added using the Add Device command. Possible values for the Address_Type parameter: 0 BR/EDR 1 LE Public 2 LE Random The event will only be sent to management sockets other than the one through which the command was sent. Device Removed Event ==================== Event Code: 0x001b Controller Index: Event Parameters: Address (6 Octets) Address_Type (1 Octet) This event indicates that a device has been removed using the Remove Device command. Possible values for the Address_Type parameter: 0 BR/EDR 1 LE Public 2 LE Random The event will only be sent to management sockets other than the one through which the command was sent. New Connection Parameter Event ============================== Event Code: 0x001c Controller Index: Event Parameters: Store_Hint (1 Octet) Param { Address (6 Octets) Address_Type (1 Octet) Min_Connection_Interval (2 Octets) Max_Connection_Interval (2 Octes) Connection_Latency (2 Octets) Supervision_Timeout (2 Octets) } This event indicates a new set of connection parameters from a peripheral device. The Store_Hint parameter indicates whether the host is expected to store this information persistently or not. Possible values for the Address_Type parameter: 0 Reserved (not in use) 1 LE Public 2 LE Random The Min_Connection_Interval, Max_Connection_Interval, Connection_Latency and Supervision_Timeout parameters are encoded as described in Core 4.1 spec, Vol 2, 7.7.65.3. Unconfigured Index Added Event ============================== Event Code: 0x001d Controller Index: Event Parameters: This event indicates that a new unconfigured controller has been added to the system. It is usually followed by a Read Controller Configuration Information command. Only when a controller requires further configuration, it will be announced with this event. If it supports configuration, but does not require it, then an Index Added event will be used. Once the Read Extended Controller Index List command has been used at least once, the Extended Index Added event will be send instead of this one. Unconfigured Index Removed Event ================================ Event Code: 0x001e Controller Index: Event Parameters: This event indicates that an unconfigured controller has been removed from the system. Once the Read Extended Controller Index List command has been used at least once, the Extended Index Removed event will be send instead of this one. New Configuration Options Event =============================== Event Code: 0x001f Controller Index: Event Parameters: Missing_Options (4 Octets) This event indicates that one or more of the options for the controller configuration has changed. Extended Index Added Event ========================== Event Code: 0x0020 Controller Index: Event Parameters: Controller_Type (1 Octet) Controller_Bus (1 Octet) This event indicates that a new controller index has been added to the system. This event will only be used after Read Extended Controller Index List has been used at least once. If it has not been used, then Index Added and Unconfigured Index Added are sent instead. Extended Index Removed Event ============================ Event Code: 0x0021 Controller Index: Event Parameters: Controller_Type (1 Octet) Controller_Bus (1 Octet) This event indicates that an existing controller index has been removed from the system. This event will only be used after Read Extended Controller Index List has been used at least once. If it has not been used, then Index Removed and Unconfigured Index Removed are sent instead. Local Out Of Band Extended Data Updated Event ============================================= Event Code: 0x0022 Controller Index: Event Parameters: Address_Type (1 Octet) EIR_Data_Length (2 Octets) EIR_Data (0-65535 Octets) This event is used when the Read Local Out Of Band Extended Data command has been used and some other user requested a new set of local out-of-band data. This allows for the original caller to adjust the data. Possible values for the Address_Type parameter are a bit-wise or of the following bits: 0 BR/EDR 1 LE Public 2 LE Random By combining these e.g. the following values are possible: 1 BR/EDR 6 LE (public & random) 7 Reserved (not in use) The value for EIR_Data_Length and content for EIR_Data is the same as described in Read Local Out Of Band Extended Data command. When LE Privacy is used and LE Secure Connections out-of-band data has been requested, then this event will be emitted every time the Resolvable Private Address (RPA) gets changed. The new RPA will be included in the EIR_Data. The event will only be sent to management sockets other than the one through which the command was sent. It will additionally also only be sent to sockets that have used the command at least once. Advertising Added Event ======================= Event Code: 0x0023 Controller Index: Event Parameters: Instance (1 Octet) This event indicates that an advertising instance has been added using the Add Advertising command. The event will only be sent to management sockets other than the one through which the command was sent. Advertising Removed Event ========================= Event Code: 0x0024 Controller Index: Event Parameters: Instance (1 Octet) This event indicates that an advertising instance has been removed using the Remove Advertising command. The event will only be sent to management sockets other than the one through which the command was sent.